Chest
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bloch, K.
Right arrow Articles by Sackner, M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Bloch, K.
Right arrow Articles by Sackner, M.

Chest, Vol 100, 371-375, Copyright © 1991 by American College of Chest Physicians


ARTICLES

Noninvasive measurement of central venous pressure by neck inductive plethysmography

KE Bloch, BP Krieger and MA Sackner
Division of Pulmonary Disease, University of Miami School of Medicine, Mount Sinai Medical Center, Miami Beach.

Bedside estimation of the height at which the internal jugular veins collapse, referenced to a standard hemodynamic location, theoretically reflects central venous pressure. This method has never been demonstrated as accurate when compared to invasive CVP measurements because of the great clinical skills and time required to visually identify the internal jugular venous waveform. Since the principles of the bedside method are sound, we utilized them in conjunction with the neck inductive plethysmograph, a device which has the capability of recording internal jugular venous and carotid arterial waveforms. The respiratory distortion of these vascular waveforms was eliminated by employing a digital bandpass filter, making it easy to identify the venous and arterial waveforms on the videoscreen of a personal computer. The upper torso was positioned while observing the videoscreen until the vascular waveform was seen as a mixed arteriovenous waveform, signifying intermittent internal jugular venous collapse. The height of the internal jugular vein above the phlebostatic axis was obtained by external measurement and recorded as CVPni in cm H2O. In 43 patients, 86 percent of CVPni (NIP) values fell within 20 percent CVPi (invasive catheter measurements) over a range of CVP from 0 to 19 cm H2O. In an additional seven patients, CVPi was greater than the height that the upper torso could be elevated and an arterial waveform could not be obtained. Here, CVPni was recorded as the value at least exceeding the value measured. In two other patients, obstruction of an internal jugular vein gave spuriously low values of CVPni. Our study indicates that this new neck inductive plethysmographic method is accurate compared to invasive catheter measurements of CVP and should serve as a safe, noninvasive alternative in situations where such measurements are required.


This article has been cited by other articles:


Home page
Behav ModifHome page
F. H. Wilhelm, W. T. Roth, and M. A. Sackner
The LifeShirt: An Advanced System for Ambulatory Measurement of Respiratory and Cardiac Function
Behav Modif, October 1, 2003; 27(5): 671 - 691.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American College of Chest Physicians.