Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fratacci, M. D.
Right arrow Articles by Laborde, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fratacci, M. D.
Right arrow Articles by Laborde, F.

Chest, Vol 102, 380-386, Copyright © 1992 by American College of Chest Physicians


ARTICLES

Doppler cardiac output and left ventricular performance after cardiac surgery. Pulsed Doppler ascending aorta and pulmonary blood flows and left ventricular function using implanted microprobes

MD Fratacci, D Payen, S Beloucif and F Laborde
Department of Anesthesiology and Intensive Care, Lariboisiere University Hospital, Paris, France.

We have developed novel implantable Doppler microprobes to monitor beat- by-beat stroke volume and cardiac output (CO) after cardiac surgery. In 11 adults undergoing either coronary artery bypass grafting (n = 6) or valve replacement (n = 5), Doppler microprobes were implanted on the ascending aorta or the main pulmonary artery to measure aortic blood flow (ABF) or pulmonary artery blood flow (PBF). The diameters of both vessels were determined before surgery using two-dimensional echocardiography. Stroke volume was obtained from velocity tracings measured by a 4-MHz zero-crossing pulsed Doppler flowmeter. Simultaneous measurements of Doppler and thermodilution CO (TDCO) were compared. We found the following: ABF = 1.03 TDCO - 0.22 L/min (r = 0.89); while PBF = 0.69 TDCO - 1.24 L/min (r = 0.75). Furthermore, peak flow velocity and maximum acceleration of blood in the ascending aorta were measured after inotropic stimulation with dobutamine; both values increased significantly from control values (25.2 +/- 6.1 percent and 44.6 +/- 8.6 percent, respectively, at 7.5 micrograms/kg/min). We conclude that implanted aortic Doppler microprobes provide a sensitive and reliable method to measure aortic blood flow velocity after surgery and then allow monitoring of stroke volume and CO and analysis of left ventricular function after cardiac surgery.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
C. J. DiCorte, P. Latham, P. E. Greilich, M. V. Cooley, P. A. Grayburn, and M. E. Jessen
Esophageal Doppler monitor determinations of cardiac output and preload during cardiac operations
Ann. Thorac. Surg., June 1, 2000; 69(6): 1782 - 1786.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American College of Chest Physicians.