Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Braun, S.
Right arrow Articles by Ellersieck, M
Right arrow Search for Related Content
PubMed
Right arrow Articles by Braun, S.
Right arrow Articles by Ellersieck, M

Chest, Vol 102, 694-698, Copyright © 1992 by American College of Chest Physicians


ARTICLES

Comparison of six oxygen delivery systems for COPD patients at rest and during exercise

SR Braun, G Spratt, GC Scott and M Ellersieck
Department of Medicine, University of Missouri-Columbia.

Five different oxygen-conserving devices were tested in each of ten oxygen-dependent patients with COPD who had met the NOTT criteria for continuous oxygen use. They were tested on room air, their prescribed continuous oxygen flow and then on each of the five devices. The devices which delivered a bolus of oxygen during early inspiration or increased oxygen delivery as the respiratory rate increased did better than those devices which delivered oxygen at a normal flow rate during inspiration or a fixed portion of inspiration. In at least one of the subjects each device was associated with desaturation to less than 80 percent during a 12-min walk. It is concluded that oxygen-conserving devices vary in their ability to maintain SaO2 levels during exercise. It is recommended that a home oxygen evaluation include measurement of an exercise SaO2 utilizing the prescribed oxygen delivery system.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
Statement on Home Care for Patients with Respiratory Disorders
Am. J. Respir. Crit. Care Med., June 15, 2005; 171(12): 1443 - 1464.
[Full Text] [PDF]


Home page
Eur Respir JHome page
Y. Lacasse, R. Lecours, C. Pelletier, R. Begin, and F. Maltais
Randomised trial of ambulatory oxygen in oxygen-dependent COPD
Eur. Respir. J., June 1, 2005; 25(6): 1032 - 1038.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
E. H. Elpern, D. Stevens, and S. Kesten
Variability in Performance of Timed Walk Tests in Pulmonary Rehabilitation Programs
Chest, July 1, 2000; 118(1): 98 - 105.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
A. Cuvelier, J.-F. Muir, P. Czernichow, E. Vavasseur, F. Portier, D. Benhamou, and D. Samson-Dolfuss
Nocturnal Efficiency and Tolerance of a Demand Oxygen Delivery System in COPD Patients With Nocturnal Hypoxemia
Chest, July 1, 1999; 116(1): 22 - 29.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
R Garrod, J C Bestall, E Paul, and J A Wedzicha
Evaluation of pulsed dose oxygen delivery during exercise in patients with severe chronic obstructive pulmonary disease
Thorax, March 1, 1999; 54(3): 242 - 244.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
Research Priorities in Respiratory Nursing
Am. J. Respir. Crit. Care Med., December 1, 1998; 158(6): 2006 - 2015.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American College of Chest Physicians.