Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rauscher, H
Right arrow Articles by Zwick, H
Right arrow Search for Related Content
PubMed
Right arrow Articles by Rauscher, H
Right arrow Articles by Zwick, H

Chest, Vol 103, 1675-1680, Copyright © 1993 by American College of Chest Physicians


ARTICLES

Self-reported vs measured compliance with nasal CPAP for obstructive sleep apnea

H Rauscher, D Formanek, W Popp and H Zwick
Pulmonary Department, Krankenhaus Lainz, Vienna, Austria.

To estimate reliability of self-reported compliance with nasal continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea (OSA), we studied 63 OSA patients aged 53.7 +/- 1.2 years (mean +/- SEM) with an apnea hypopnea index (AHI) of 50.8 +/- 2.9 and lowest sleep SaO2 of 65.6 +/- 2.3 percent receiving nasal CPAP for 539 +/- 44 days. During a follow-up polysomnography (PSG) on the pressure prescribed for home therapy (10.3 +/- 0.3 cm H2O), the hours of operation shown on the built-in time counter of the patients' devices were read to determine objective compliance by dividing the run time by the days since initiation of therapy. This parameter was compared with subjective compliance reported in a self-administered questionnaire. Mean measured use time was 4.9 +/- 0.3 h per night, whereas reported daily use time calculated from reported nights a week and hours a night was 6.1 +/- 0.3 h per night. As predominantly patients with poor compliance misestimated daily use time, we conclude that self-reports are unable to distinguish between compliant and noncompliant patients.


This article has been cited by other articles:


Home page
ChestHome page
B. Mokhlesi and A. Tulaimat
Recent Advances in Obesity Hypoventilation Syndrome
Chest, October 1, 2007; 132(4): 1322 - 1336.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
L. S. Doherty, J. L. Kiely, V. Swan, and W. T. McNicholas
Long-term Effects of Nasal Continuous Positive Airway Pressure Therapy on Cardiovascular Outcomes in Sleep Apnea Syndrome
Chest, June 1, 2005; 127(6): 2076 - 2084.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M.R. Wild, H.M. Engleman, N.J. Douglas, and C.A. Espie
Can psychological factors help us to determine adherence to CPAP? A prospective study
Eur. Respir. J., September 1, 2004; 24(3): 461 - 465.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
C. A. Massie and R. W. Hart
Clinical Outcomes Related to Interface Type in Patients With Obstructive Sleep Apnea/Hypopnea Syndrome Who Are Using Continuous Positive Airway Pressure
Chest, April 1, 2003; 123(4): 1112 - 1118.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
F. Lofaso and M.A. Quera-Salva
Polysomnography for the management of progressive neuromuscular disorders
Eur. Respir. J., June 1, 2002; 19(6): 989 - 990.
[Full Text] [PDF]


Home page
ChestHome page
D. D. Sin, I. Mayers, G. C. W. Man, and L. Pawluk
Long-term Compliance Rates to Continuous Positive Airway Pressure in Obstructive Sleep Apnea : A Population-Based Study
Chest, February 1, 2002; 121(2): 430 - 435.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. S. C Hui, D. K. L. Choy, T. S. T. Li, F. W. S. Ko, K. K. Wong, J. K. W. Chan, and C. K. W. Lai
Determinants of Continuous Positive Airway Pressure Compliance in a Group of Chinese Patients With Obstructive Sleep Apnea
Chest, July 1, 2001; 120(1): 170 - 176.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. S. C. Hui, J. K. W. Chan, D. K. L. Choy, F. W. S. Ko, T. S. T. Li, R. C. C. Leung, and C. K. W. Lai
Effects of Augmented Continuous Positive Airway Pressure Education and Support on Compliance and Outcome in a Chinese Population
Chest, May 1, 2000; 117(5): 1410 - 1416.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
P. Lavie
Treatment of Sleep Apnea : Unmet Needs
Chest, December 1, 1999; 116(6): 1501 - 1503.
[Full Text] [PDF]


Home page
BMJHome page
J. Wright, R. Johns, I. Watt, A. Melville, and T. Sheldon
Health effects of obstructive sleep apnoea and the effectiveness of continuous positive airways pressure: a systematic review of the research evidence
BMJ, March 22, 1997; 314(7084): 851 - 851.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American College of Chest Physicians.