Guest Access | Sign In via User Name/Password |
|||||||||
Chest, Vol 105, 343-348, Copyright © 1994 by American College of Chest Physicians
ARTICLES |
P Carre, H Rousseau, L Lombart, A Didier, M Dahan, G Fournial and P Leophonte
Rangueil Hospital, Toulouse, France.
Here we report our experience on the use of balloon dilatation or self- expandable metal Wallstent implantation, or both, for the management of twelve bronchial stenoses in ten lung transplant recipients during the past two years. Both techniques were carried out endoscopically, under fluoroscopic guidance and without general anesthesia. Both methods were straightforward, well tolerated, and resulted in immediate symptomatic and functional improvement. The first-line treatment relied on Wallstent insertion (n = 4) or on balloon dilatation (n = 8). Early restenosis occurred in four of eight dilated stenoses and subsequently led to Wallstent insertion. Following Wallstent implantation, growth of granulation tissue occurred in one case and necessitated repeated balloon dilatations inside the stent during the following months. On two occasions, the stenosis was located such that the lower end of the Wallstent overlapped the upper lobe bronchus orifice. This necessitated laser therapy to eliminate the filaments of the stent crossing the lobar orifice, preventing subsequent obstruction. Laser therapy was followed, in one case, by a fibroinflammatory stenosis which was successfully treated by balloon dilatation inside the prosthesis. At the time of writing, the mean +/- SE of the follow-up after Wallstent implantation is 15.3 +/- 2.7 (range: 6 to 32) months. Most Wallstent prostheses are overgrown with bronchial epithelium. We conclude (1) that self-expanding metal Wallstent implantation is a safe procedure and good alternative to silicone stent insertion for the treatment of bronchostenosis following lung transplantation, provided granulomas are not present and (2) that balloon dilatation, although possibly leading to recurrences, can be used to allow inflammatory tissue to mature or to dilate restenoses inside the Wallstent.
This article has been cited by other articles:
![]() |
Y H Kim, D J Sung, S B Cho, K B Chung, S H Cha, H S Park, and J W Um Deep tracheal laceration after balloon dilation for benign tracheobronchial stenosis: case reports of two patients. Br. J. Radiol., June 1, 2006; 79(942): 529 - 535. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. M. Mughal, T. R. Gildea, S. Murthy, G. Pettersson, M. DeCamp, and A. C. Mehta Short-Term Deployment of Self-Expanding Metallic Stents Facilitates Healing of Bronchial Dehiscence Am. J. Respir. Crit. Care Med., September 15, 2005; 172(6): 768 - 771. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Lemaire, W. R. Burfeind, E. Toloza, S. Balderson, R. P. Petersen, D. H. Harpole Jr, and T. A. D'Amico Outcomes of Tracheobronchial Stents in Patients With Malignant Airway Disease Ann. Thorac. Surg., August 1, 2005; 80(2): 434 - 438. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. B. Pillai, J. Smith, A. Hasan, and D. Spencer Review of pediatric airway malacia and its management, with emphasis on stenting Eur. J. Cardiothorac. Surg., January 1, 2005; 27(1): 35 - 44. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. P. Saad, S. Murthy, G. Krizmanich, and A. C. Mehta Self-Expandable Metallic Airway Stents and Flexible Bronchoscopy: Long-term Outcomes Analysis Chest, November 1, 2003; 124(5): 1993 - 1999. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Hauck, M. Barbur, R. Lembeck, F. Peltz, and M. Werner Cellular Composition of Stent-Penetrating Tissue Chest, November 1, 2002; 122(5): 1615 - 1621. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. N. Chhajed, M. A. Malouf, M. Tamm, P. Spratt, and A. R. Glanville Interventional Bronchoscopy for the Management of Airway Complications Following Lung Transplantation Chest, December 1, 2001; 120(6): 1894 - 1899. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. G. KADITIS, M. GONDOR, P. A. NIXON, S. WEBBER, R. J. KEENAN, R. KAYE, and G. KURLAND Airway Complications Following Pediatric Lung and Heart-Lung Transplantation Am. J. Respir. Crit. Care Med., July 1, 2000; 162(1): 301 - 309. [Abstract] [Full Text] |
||||
![]() |
H.-Y. Song, T. S. Shim, S.-G. Kang, G.-S. Jung, D. Y. Lee, T.-H. Kim, S. Park, Y. M. Ahn, and W. S. Kim Tracheobronchial Strictures: Treatment with a Polyurethane-covered Retrievable Expandable Nitinol Stent-Initial Experience Radiology, December 1, 1999; 213(3): 905 - 912. [Abstract] [Full Text] |
||||
![]() |
V. A. Lonchyna, J. M. Arcidi Jr., E. R. Garrity Jr., K. Simpson, C. Alex, V. Yeldandi, and M. Bakhos Refractory post-transplant airway strictures: successful management with wire stents Eur. J. Cardiothorac. Surg., June 1, 1999; 15(6): 842 - 850. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. D. Eisner, R. L. Gordon, W. R. Webb, W. M. Gold, S. E. Hilal, K. Edinburgh, and J. A. Golden Pulmonary Function Improves After Expandable Metal Stent Placement for Benign Airway Obstruction Chest, April 1, 1999; 115(4): 1006 - 1011. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. H. Marquette, E. Mensier, M.-C. Copin, A. Desmidt, L. Freitag, C. Witt, L. Petyt, and P. Ramon Experimental Models of Tracheobronchial Stenoses: A Useful Tool for Evaluating Airway Stents Ann. Thorac. Surg., September 1, 1995; 60(3): 651 - 656. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |