Chest
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, K.
Right arrow Articles by Lim, T.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Lee, K.
Right arrow Articles by Lim, T.

Chest, Vol 105, 540-543, Copyright © 1994 by American College of Chest Physicians


ARTICLES

Rapid shallow breathing (frequency-tidal volume ratio) did not predict extubation outcome

KH Lee, KP Hui, TB Chan, WC Tan and TK Lim
Department of Medicine, National University Hospital, Singapore.

This was a prospective study of 52 patients that were extubated in our medical intensive care unit. Rapid shallow breathing, represented by a ratio of frequency to tidal volume (f/VT) of more than 105, was evaluated either on continuous positive airway pressure or pressure support prior to extubation as a marker of extubation outcome. Twelve out of 13 patients (92 percent) with rapid shallow breathing (f/VT ratio > 105) were successfully extubated. Out of 9 extubation failures only 1 patient had a f/VT ratio more than 105 (11 percent). A measured f/VT ratio of less than 105 had a sensitivity and specificity of 72 and 11 percent, respectively, for extubation success. Patients who had unsuccessful outcomes were ventilated for a significantly more prolonged period (9.6 +/- 6.8 d vs 4.6 +/- 3.9 d, unpaired t test, p = 0.004). We conclude that the presence of rapid shallow breathing during a weaning trial with the patient on partial ventilatory support does not necessarily preclude successful extubation.


This article has been cited by other articles:


Home page
ChestHome page
A. Martinez, C. Seymour, and M. Nam
Minute Ventilation Recovery Time: A Predictor of Extubation Outcome
Chest, April 1, 2003; 123(4): 1214 - 1221.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
B. P. Krieger and M. Campos
Weaning Parameters: Read the Methodology Before Proceeding
Chest, December 1, 2002; 122(6): 1873 - 1874.
[Full Text] [PDF]


Home page
ChestHome page
J. D. Cohen, M. Shapiro, E. Grozovski, and P. Singer
Automatic Tube Compensation-Assisted Respiratory Rate to Tidal Volume Ratio Improves the Prediction of Weaning Outcome*
Chest, September 1, 2002; 122(3): 980 - 984.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement on Respiratory Muscle Testing
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624.
[Full Text] [PDF]


Home page
ChestHome page
G. W. Soo Hoo and L. Park
Variations in the Measurement of Weaning Parameters* : A Survey of Respiratory Therapists
Chest, June 1, 2002; 121(6): 1947 - 1955.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. Meade, G. Guyatt, D. Cook, L. Griffith, T. Sinuff, C. Kergl, J. Mancebo, A. Esteban, and S. Epstein
Predicting Success in Weaning From Mechanical Ventilation
Chest, December 1, 2001; 120(6_suppl): 400S - 424S.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
S. Edmunds, I. Weiss, and R. Harrison
Extubation Failure in a Large Pediatric ICU Population
Chest, March 1, 2001; 119(3): 897 - 900.
[Abstract] [Full Text] [PDF]


Home page
Med Decis MakingHome page
A. Gottschalk, M. C. Hyzer, and R. T. Geer
A Comparison of Human and Machine-based Predictions of Successful Weaning from Mechanical Ventilation
Med Decis Making, April 1, 2000; 20(2): 160 - 169.
[Abstract] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. MALDONADO, T. T. BAUER, M. FERRER, C. HERNANDEZ, F. ARANCIBIA, R. RODRIGUEZ-ROISIN, and A. TORRES
Capnometric Recirculation Gas Tonometry and Weaning from Mechanical Ventilation
Am. J. Respir. Crit. Care Med., January 1, 2000; 161(1): 171 - 176.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. R. THIAGARAJAN, S. L. BRATTON, L. D. MARTIN, T. V. BROGAN, and D. TAYLOR
Predictors of Successful Extubation in Children
Am. J. Respir. Crit. Care Med., November 1, 1999; 160(5): 1562 - 1566.
[Abstract] [Full Text]


Home page
ChestHome page
B. Afessa, L. Hogans, and R. Murphy
Predicting 3-Day and 7-Day Outcomes of Weaning From Mechanical Ventilation
Chest, August 1, 1999; 116(2): 456 - 461.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. A. Price and N. W. Rizk
Postoperative Ventilatory Management
Chest, May 1, 1999; 115(suppl_2): 130S - 137S.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
I. VALLVERDU, N. CALAF, M. SUBIRANA, A. NET, S. BENITO, and J. MANCEBO
Clinical Characteristics, Respiratory Functional Parameters, and Outcome of a Two-Hour T-Piece Trial in Patients Weaning from Mechanical Ventilation
Am. J. Respir. Crit. Care Med., December 1, 1998; 158(6): 1855 - 1862.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
S. K. EPSTEIN and R. L. CIUBOTARU
Independent Effects of Etiology of Failure and Time to Reintubation on Outcome for Patients Failing Extubation
Am. J. Respir. Crit. Care Med., August 1, 1998; 158(2): 489 - 493.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
S. E. Weinberger and J. W. Weiss
Weaning from Ventilatory Support
N. Engl. J. Med., February 9, 1995; 332(6): 388 - 389.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the American College of Chest Physicians.