Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smithline, H.
Right arrow Articles by Nowak, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smithline, H.
Right arrow Articles by Nowak, R.

Chest, Vol 105, 842-846, Copyright © 1994 by American College of Chest Physicians


ARTICLES

Biphasic extrathoracic pressure CPR. A human pilot study

HA Smithline, EP Rivers, MY Rady, HC Blake and RM Nowak
Department of Emergency Medicine, Henry Ford Health Systems, Henry Ford Hospital, Detroit.

HYPOTHESIS: Alternating intrathoracic pressure by means of a chest cuirass can cause perfusion and ventilation equal to or better than standard cardiopulmonary resuscitation (CPR) for humans in cardiac arrest. DESIGN: Nonrandomized, nonblinded, crossover pilot study. SETTING: Large urban emergency department. SUBJECTS: Five adult normothermic, nontraumatic, out-of-hospital cardiac arrest patients unresponsive to standard advanced cardiac life support. METHOD: Right atrial and aortic catheters were inserted for pressure measurement and blood gas analysis while the patient was receiving standard CPR by a pneumatic compression device (Thumper). The Thumper was then replaced by a chest cuirass (Hayek Oscillator). Pressure and blood gas measurements were then repeated. RESULTS: The coronary perfusion pressure increased from -1.2 +/- 8.6 mm Hg to 6.2 +/- 6.9 mm Hg for a mean change of 7.4 +/- 3.1 mm Hg (p = 0.006). The compression phase gradient increased 10.0 +/- 21.9 mm Hg (p = 0.364). The venous to arterial PCO2 gradient decreased 44.5 +/- 32.3 mm Hg (p = 0.070). The oxygen extraction ratio increased 1.6 +/- 9.4 percent (p = 0.761). The mean arterial PO2 and PCO2 changed from 252 to 240 mm Hg (p = 0.836) and from 53 to 66 (p = 0.172) mm Hg, respectively. CONCLUSION: The Hayek Oscillator chest cuirass produced a significant improvement in the coronary perfusion pressure. There was a trend for improved systemic perfusion as indicated by an improved compression phase gradient and venous to arterial PCO2 gradient, although this was not supported by the lack of improvement in the oxygen extraction ratio. The cuirass also adequately oxygenates and ventilates unassisted by positive pressure ventilation.


This article has been cited by other articles:


Home page
Br J AnaesthHome page
S. E. Scholz, J. Sticher, G. Haufler, M. Muller, O. Boning, and G. Hempelmann
Combination of external chest wall oscillation with continuous positive airway pressure
Br. J. Anaesth., September 1, 2001; 87(3): 441 - 446.