Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Anzueto, A
Right arrow Articles by Bryan, C.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Anzueto, A
Right arrow Articles by Bryan, C.

Chest, Vol 105, 934-936, Copyright © 1994 by American College of Chest Physicians


ARTICLES

Use of the flow-volume loop in the diagnosis of bronchial stenosis after single lung transplantation

A Anzueto, SM Levine, WP Tillis, JH Calhoon and CL Bryan
Department of Medicine (Division of Pulmonary Diseases), University of Texas Health Science Center at San Antonio.

Bronchial complications, including stricture, stenosis, and/or anastomotic dehiscence, are a major cause of morbidity following single lung transplantation. This report describes a 19-year-old man with a diagnosis of end-stage pulmonary fibrosis secondary to prior chemotherapy for non-Hodgkins lymphoma who underwent single lung transplantation. The immunosuppressive regimen included cyclosporine, azathioprine, and methylprednisolone sodium succinate (Solu-Medrol) intravenously for six doses during the first 3 days postoperatively followed by oral prednisone. Sixteen weeks following transplantation, the patient complained of dyspnea. Spirometry revealed a decrease in FEF25-75 and the flow-volume curve demonstrated a bioconcave appearance. The flow-volume loop showed a relatively high initial flow phase occurring over the first 2 to 3 s followed by a low-flow phase. The expiratory phase also showed the same characteristics. Bronchoscopy revealed 75 percent stenosis of the bronchial lumen to the transplanted lung. A transbronchial biopsy specimen obtained at that time was consistent with acute rejection. The patient was treated with a methylprednisolone bolus. A repeated bronchoscopy showed the persistence of stenosis distal to the anastomosis. The patient underwent several bronchoplastic balloon dilatations without complete resolution of the stenosis and a stainless steel mesh stent was placed. Repeated spirometry showed marked improvement of the FEF25-75 and normalization of the flow-volume loop. We conclude that the flow-volume loop curve is a noninvasive procedure that may help monitor the patency of the bronchial anastomoses following single lung transplantation.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
K. E.A. Burns, P. D. Orons, J. H. Dauber, W. F. Grgurich, L. W. Stitt, S. Raghu, and A. T. Iacono
Endobronchial metallic stent placement for airway complications after lung transplantation: Longitudinal results
Ann. Thorac. Surg., December 1, 2002; 74(6): 1934 - 1941.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
V. A. Lonchyna, J. M. Arcidi Jr., E. R. Garrity Jr., K. Simpson, C. Alex, V. Yeldandi, and M. Bakhos
Refractory post-transplant airway strictures: successful management with wire stents
Eur. J. Cardiothorac. Surg., June 1, 1999; 15(6): 842 - 850.
[Abstract] [Full Text] [PDF]