Chest Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meyer, T. J.
Right arrow Articles by Millman, R. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meyer, T. J.
Right arrow Articles by Millman, R. P.

Chest, Vol 105, 1211-1216, Copyright © 1994 by American College of Chest Physicians


ARTICLES

Adverse environmental conditions in the respiratory and medical ICU settings

TJ Meyer, SE Eveloff, MS Bauer, WA Schwartz, NS Hill and RP Millman
Department of Medicine, Rhode Island Hospital, Providence 02903.

Sleep deprivation and fragmentation occurring in the hospital setting may have a negative impact on the respiratory system by decreasing respiratory muscle function and ventilatory response to CO2. Sleep deprivation in a patient with respiratory failure may, therefore, impair recovery and weaning from mechanical ventilation. We postulate that light, sound, and interruption levels in a weaning unit are major factors resulting in sleep disorders and possibly circadian rhythm disruption. As an initial test of this hypothesis, we sampled interruption levels and continuously monitored light and sound levels for a minimum of seven consecutive days in a medical ICU, a multiple bed respiratory care unit (RCU) room, a single-bed RCU room, and a private room. Light levels in all areas maintained a day-night rhythm, with peak levels dependent on window orientation and shading. Peak sound levels were extremely high in all areas representing values significantly higher than those recommended by the Environmental Protection Agency as acceptable for a hospital environment. The number of sound peaks greater than 80 decibels, which may result in sleep arousals, was especially high in the intensive and respiratory care areas, but did show a day-night rhythm in all settings. Patient interruptions tended to be erratic, leaving little time for condensed sleep. We conclude that the potential for environmentally induced sleep disruption is high in all areas, but especially high in the intensive and respiratory care areas where the negative consequences may be the most severe.


This article has been cited by other articles:


Home page
ChestHome page
K. A. Hardin, M. Seyal, T. Stewart, and H. W. Bonekat
Sleep in Critically Ill Chemically Paralyzed Patients Requiring Mechanical Ventilation
Chest, June 1, 2006; 129(6): 1468 - 1477.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J. Y. Gabor, A. B. Cooper, S. A. Crombach, B. Lee, N. Kadikar, H. E. Bettger, and P. J. Hanly
Contribution of the Intensive Care Unit Environment to Sleep Disruption in Mechanically Ventilated Patients and Healthy Subjects
Am. J. Respir. Crit. Care Med., March 1, 2003; 167(5): 708 - 715.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
B. Allaouchiche, F. Duflo, R. Debon, A. Bergeret, and D. Chassard
Noise in the postanaesthesia care unit
Br. J. Anaesth., March 1, 2002; 88(3): 369 - 373.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
H. M. Soliman, C. Melot, and J.-L. Vincent
Sedative and analgesic practice in the intensive care unit: the results of a European survey
Br. J. Anaesth., August 1, 2001; 87(2): 186 - 192.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
N. S. FREEDMAN, J. GAZENDAM, L. LEVAN, A. I. PACK, and R. J. SCHWAB
Abnormal Sleep/Wake Cycles and the Effect of Environmental Noise on Sleep Disruption in the Intensive Care Unit
Am. J. Respir. Crit. Care Med., February 1, 2001; 163(2): 451 - 457.
[Abstract] [Full Text]


Home page
ChestHome page
A. B. Cooper, K. S. Thornley, G. B. Young, A. S. Slutsky, T. E. Stewart, and P. J. Hanly
Sleep in Critically Ill Patients Requiring Mechanical Ventilation
Chest, March 1, 2000; 117(3): 809 - 818.
[Abstract] [Full Text] [PDF]


Home page
J Intensive Care MedHome page
R. J. Berens
Noise in the Pediatric Intensive Care Unit: Berens RJ Noise in the pediatric intensive care unit J Intensive Care Med 1999,14 118-129
J Intensive Care Med, May 1, 1999; 14(3): 118 - 129.
[PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
N. S. FREEDMAN, N. KOTZER, and R. J. SCHWAB
Patient Perception of Sleep Quality and Etiology of Sleep Disruption in the Intensive Care Unit
Am. J. Respir. Crit. Care Med., April 1, 1999; 159(4): 1155 - 1162.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the American College of Chest Physicians.