Chest ACCP Career Connection
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pépin, J. L.
Right arrow Articles by Lévy, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pépin, J. L.
Right arrow Articles by Lévy, P.
(Chest. 1995;107:375-381.)
© 1995 American College of Chest Physicians

Side Effects of Nasal Continuous Positive Airway Pressure in Sleep Apnea Syndrome

Study of 193 Patients in Two French Sleep Centers

Jean Louis Pépin MD1; Patrick Leger MD2; Dan Veale MD3; Bruno Langevin MD2; Dominique Robert MD2; and Patrick Lévy MD, PhD4

1 From the Department of Respiratory Medicine (Pr Paramelle, Pr Brambilla) and Sleep Laboratory, CHRU de Grenoble, France
2 From the Intensive Care Unit (Pr Robert), and Respiratory Sleep Disorders Laboratory (LRTS), SRMAR, Hopital de la Croix-Rousse, Lyon, France
3 From the Department of Respiratory Medicine (Pr Paramelle, Pr Brambilla) and Sleep Laboratory, CHRU de Grenoble, France; the Departments of Respiratory and General Medicine, Sunderland Royal Infirmary, England
4 From the Department of Respiratory Medicine (Pr Paramelle, Pr Brambilla) and Sleep Laboratory, CHRU de Grenoble, France; and the PRETA Laboratory, Department of Physiology, Faculty of Medicine, Joseph Fourier University, Grenoble, France

Nasal continuous positive airway pressure (N-CPAP) is now the treatment of choice for patients with sleep apnea syndrome (SAS). Side effects and adverse reactions have been described with this device. We have therefore systematically studied side effects of N-CPAP in 193 patients recruited consecutively from two French sleep centers (Lyon and Grenoble). Patients were followed up with repeated polysomnography, clinical assessment, and a formal questionnaire about subjective benefits and side effects of treatment. The patients (mean age, 59±12 years) were obese (body mass index, 32±7 kg/m2) and had been using N-CPAP for 19±17 months for moderate to severe SAS (respiratory disturbance index [RDI]=53±25/h). The clinical presentation was the same in the two sleep centers. Fifty percent of the patients complained of at least one side effect due to the nasal mask (allergy to the face, air leaks, abrasions of the ridge of the nose). Using individually molded masks, the patients exhibited fewer abrasions of the bridge of the nose (p<0.01) and had red eyes every morning in only 9% of cases vs 24% for the patients using industrial silicone nasal masks (p<0.025). Patients with silicone nasal masks also had more allergic reaction to the face (13% vs 5%), but this difference did not reach significance. Dry nose or mouth in the morning affected 65% of the patients. Sneezing and nasal drip were present in more than 35% of the subjects and nasal congestion in 25%. When the patients were separated in two groups, whether or not using a humidifier, no difference was found for any of the side effects described. The clinical presentation as to the clinical benefits obtained from N-CPAP were different when comparing mild vs moderate-to-severe SAS. However, no differences were shown in the two subgroups regarding the side effects due to the nasal mask. The discomfort of the N-CPAP apparatus in terms of noise was described more frequently in the subgroup with mild SAS. We did not observe any correlation between the side effects and the level of pressure used during N-CPAP. The rate of compliance remains high with a daily use of 6.5±3 h, with 88% of the patients using their device every night. This could be explained by the clinical benefit obtained: only 1% of the patients had no subjective benefit induced by their therapy. Snoring and daytime sleepiness were relieved in more than 65% of the subjects and sleep quality improved in 75%. In the present study, we have confirmed in two different centers in France that side effects were frequent during N-CPAP treatment. From this study, it also appears that the incidence of nasal side effects can be reduced with appropriate follow-up.

Key Words: N-CPAP • side effects • sleep apnea

Submitted on November 12, 1993
Accepted on August 2, 1994




This article has been cited by other articles:


Home page
Arch Otolaryngol Head Neck SurgHome page
H.-S. Lin, A. S. Prasad, C.-J. G. Pan, and J. A. Rowley
Factors Associated With Noncompliance to Treatment With Positive Airway Pressure
Arch Otolaryngol Head Neck Surg, January 1, 2007; 133(1): 69 - 72.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
G. Nilius, A. Happel, U. Domanski, and K.-H. Ruhle
Pressure-Relief Continuous Positive Airway Pressure vs Constant Continuous Positive Airway Pressure: A Comparison of Efficacy and Compliance.
Chest, October 1, 2006; 130(4): 1018 - 1024.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. Rigau, J. M. Montserrat, H. Wohrle, D. Plattner, M. Schwaibold, D. Navajas, and R. Farre
Bench model to simulate upper airway obstruction for analyzing automatic continuous positive airway pressure devices.
Chest, August 1, 2006; 130(2): 350 - 361.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M. Duong, L. Jayaram, D. Camfferman, P. Catcheside, I. Mykytyn, and R. D. McEvoy
Use of heated humidification during nasal CPAP titration in obstructive sleep apnoea syndrome
Eur. Respir. J., October 1, 2005; 26(4): 679 - 685.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. J. Mador, M. Krauza, A. Pervez, D. Pierce, and M. Braun
Effect of Heated Humidification on Compliance and Quality of Life in Patients With Sleep Apnea Using Nasal Continuous Positive Airway Pressure
Chest, October 1, 2005; 128(4): 2151 - 2158.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
P Gordon and M H Sanders
Sleep {middle dot} 7: Positive airway pressure therapy for obstructive sleep apnoea/hypopnoea syndrome
Thorax, January 1, 2005; 60(1): 68 - 75.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
A. Bachour and P. Maasilta
Mouth Breathing Compromises Adherence to Nasal Continuous Positive Airway Pressure Therapy
Chest, October 1, 2004; 126(4): 1248 - 1254.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
F. Gagnadoux, X.L. Nguyen, D. Rakotonanahary, S. Vidal, and B. Fleury
Wrist-actigraphic estimation of sleep time under nCPAP treatment in sleep apnoea patients
Eur. Respir. J., June 1, 2004; 23(6): 891 - 895.
[Abstract] [Full Text] [PDF]


Home page
Crit. Rev. Oral Biol. Med.Home page
A. Hoekema, B. Stegenga, and L.G.M. de Bont
EFFICACY AND CO-MORBIDITY OF ORAL APPLIANCES IN THE TREATMENT OF OBSTRUCTIVE SLEEP APNEA-HYPOPNEA: A SYSTEMATIC REVIEW
Crit. Rev. Oral. Biol. Med., May 1, 2004; 15(3): 137 - 155.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
A.M. Neill, H.S. Wai, S.P.T. Bannan, C.R. Beasley, M. Weatherall, and A.J. Campbell
Humidified nasal continuous positive airway pressure in obstructive sleep apnoea
Eur. Respir. J., August 1, 2003; 22(2): 258 - 262.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
C. A. Massie and R. W. Hart
Clinical Outcomes Related to Interface Type in Patients With Obstructive Sleep Apnea/Hypopnea Syndrome Who Are Using Continuous Positive Airway Pressure
Chest, April 1, 2003; 123(4): 1112 - 1118.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. F. Fitzpatrick, C. E. D. Alloway, T. M. Wakeford, A. W. MacLean, P. W. Munt, and A. G. Day
Can Patients with Obstructive Sleep Apnea Titrate Their Own Continuous Positive Airway Pressure?
Am. J. Respir. Crit. Care Med., March 1, 2003; 167(5): 716 - 722.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
F.-X. Petit, J.-L. Pepin, G. Bettega, H. Sadek, B. Raphael, and P. Levy
Mandibular Advancement Devices: Rate of Contraindications in 100 Consecutive Obstructive Sleep Apnea Patients
Am. J. Respir. Crit. Care Med., August 1, 2002; 166(3): 274 - 278.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
B.M. Sanner, M. Heise, B. Knoben, M. Machnick, U. Laufer, R. Kikuth, W. Zidek, and B. Hellmich
MRI of the pharynx and treatment efficacy of a mandibular advancement device in obstructive sleep apnoea syndrome
Eur. Respir. J., July 1, 2002; 20(1): 143 - 150.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
W.J. Randerath, J. Meier, H. Genger, U. Domanski, and K-H. Ruhle
Efficiency of cold passover and heated humidification under continuous positive airway pressure
Eur. Respir. J., July 1, 2002; 20(1): 183 - 186.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. Rakotonanahary, N. Pelletier-Fleury, F. Gagnadoux, and B. Fleury
Predictive Factors for the Need for Additional Humidification During Nasal Continuous Positive Airway Pressure Therapy
Chest, February 1, 2001; 119(2): 460 - 465.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
G. BETTEGA, J.-L. PEPIN, D. VEALE, C. DESCHAUX, B. RAPHAEL, and P. LEVY
Obstructive Sleep Apnea Syndrome . Fifty-one Consecutive Patients Treated by Maxillofacial Surgery
Am. J. Respir. Crit. Care Med., August 1, 2000; 162(2): 641 - 649.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. Kindgen-Milles, R. Buhl, A. Gabriel, H. Bohner, and E. Muller
Nasal Continuous Positive Airway Pressure: A Method to Avoid Endotracheal Reintubation in Postoperative High-risk Patients With Severe Nonhypercapnic Oxygenation Failure
Chest, April 1, 2000; 117(4): 1106 - 1111.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
L. K. Brown
Back to Basics: If It’s Dry, Wet It : The Case for Humidification of Nasal Continuous Positive Airway Pressure Air
Chest, March 1, 2000; 117(3): 617 - 619.
[Full Text] [PDF]


Home page
ChestHome page
M. T. Martins de Araujo, S. B. Vieira, E. C. Vasquez, and B. Fleury
Heated Humidification or Face Mask To Prevent Upper Airway Dryness During Continuous Positive Airway Pressure Therapy*
Chest, January 1, 2000; 117(1): 142 - 147.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J. L. PÉPIN, J. KRIEGER, D. RODENSTEIN, A. CORNETTE, E. SFORZA, P. DELGUSTE, C. DESCHAUX, V. GRILLIER, and P. LÉVY
Effective Compliance during the First 3 Months of Continuous Positive Airway Pressure . A European Prospective Study of 121 Patients
Am. J. Respir. Crit. Care Med., October 1, 1999; 160(4): 1124 - 1129.
[Abstract] [Full Text]


Home page
ChestHome page
C. A. Massie, R. W. Hart, K. Peralez, and G. N. Richards
Effects of Humidification on Nasal Symptoms and Compliance in Sleep Apnea Patients Using Continuous Positive Airway Pressure
Chest, August 1, 1999; 116(2): 403 - 408.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
K.G. van Houwelingen, R. van Uffelen, and A.C.M. van Vliet
The sleep apnoea syndromes
Eur. Heart J., June 2, 1999; 20(12): 858 - 866.
[PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
N. MCARDLE, G. DEVEREUX, H. HEIDARNEJAD, H. M. ENGLEMAN, T. W. MACKAY, and N. J. DOUGLAS
Long-term Use of CPAP Therapy for Sleep Apnea/Hypopnea Syndrome
Am. J. Respir. Crit. Care Med., April 1, 1999; 159(4): 1108 - 1114.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
R. Jokic, A. Klimaszewski, M. Crossley, G. Sridhar, and M. F. Fitzpatrick
Positional Treatment vs Continuous Positive Airway Pressure in Patients With Positional Obstructive Sleep Apnea Syndrome
Chest, March 1, 1999; 115(3): 771 - 781.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American College of Chest Physicians.