Chest Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lofaso, F.
Right arrow Articles by Isabey, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lofaso, F.
Right arrow Articles by Isabey, D.
(Chest. 1995;108:772-778.)
© 1995 American College of Chest Physicians

Evaluation of Carbon Dioxide Rebreathing During Pressure Support Ventilation With Airway Management System (BiPAP) Devices

Frédéric Lofaso MD1; Laurent Brochard MD2; Dominique Touchard 1; Thierry Hang 3; Main Harf MD1; and Daniel Isabey PhD1

1 From the Service de Physiologie-Explorations Fonctionelles and Institut National de la Santé et de la Recherche Medical (INSERM) U 296, Hopital Henri Mondor, Creteil, France
2 From the Reanimation Medicale; Hopital Henri Mondor, Creteil, France
3 From the Association d'Entraide des Polios et Handicapes, Puteaux, France

The purpose of this study was to evaluate whether carbon dioxide (CO2) rebreathing occurs in acute respiratory failure patients ventilated using the standard airway management system (BiPAP pressure support ventilator; Respironics; Murrysville, Pa) with positive inspiratory airway pressure and a minimal level of positive end-expiratory pressure (PEEP) and whether any CO2 rebreathing may be efficiently prevented by the addition of a nonrebreathing valve to the BiPAP system circuit. In the first part of the study, the standard device was tested on a lung model with a nonrebreathing valve (BiPAP-NRV) and with the usual Whisper Swivel connector (BiPAP-uc). With the BiPAP-uc device, the resident volume of expired air in the inspiratory circuit at the end of expiration (RVEA) was 55% of the tidal volume (VT) when the inspiratory pressure was 10 cm H2O and the frequency was at 15 cycles per minute. The BiPAP-NRV device efficiently prevented CO2 rebreathing but resulted in a slight decrease in Vt, which was due to a significant increase in external PEEP (2.4 vs 1.3 cm H2O) caused by the additional expiratory valve resistance. For similar reasons, both the pressure swing necessary to trigger pressure support and the imposed expiratory work were increased in the lung model when the nonrebreathing valve was used. In the second part of the study, seven patients weaned from mechanical ventilation were investigated using a randomized crossover design to compare three situations: pressure support ventilation with a conventional intensive care ventilator (CIPS), BiPAP system use, and BiPAP-NRV. When we compared the BiPAP system use with the other two systems, we observed no significant effect on blood gases but found significant increases in VT, minute ventilation, and work of breathing. These findings are experimental and are clinical evidence that significant CO2 rebreathing occurs with the standard BiPAP system. This drawback can be overcome by using a nonrebreathing valve, but only at the expense of greater expiratory resistance.

Key Words: bilevel positive airway pressure • CO2-rebreathing • pressure support • work of breathing

Submitted on October 12, 1994
Accepted on February 2, 1995




This article has been cited by other articles:


Home page
ChestHome page
F. Lofaso, G. Desmarais, K. Leroux, V. Zalc, R. Fodil, D. Isabey, and B. Louis
Bench evaluation of flow limitation detection by automated continuous positive airway pressure devices.
Chest, August 1, 2006; 130(2): 343 - 349.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M.W. Elliott
The interface: crucial for successful noninvasive ventilation
Eur. Respir. J., January 1, 2004; 23(1): 7 - 8.
[Full Text] [PDF]


Home page
Eur Respir JHome page
E. Saatci, D.M. Miller, I.M. Stell, K.C. Lee, and J. Moxham
Dynamic dead space in face masks used with noninvasive ventilators: a lung model study
Eur. Respir. J., January 1, 2004; 23(1): 129 - 135.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M.P. Highcock, J.M. Shneerson, and I.E. Smith
Increased ventilation with NiIPPV does not necessarily improve exercise capacity in COPD
Eur. Respir. J., July 1, 2003; 22(1): 100 - 105.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
N. S. Hill, C. Carlisle, and N. R. Kramer
Effect of a Nonrebreathing Exhalation Valve on Long-term Nasal Ventilation Using a Bilevel Device*
Chest, July 1, 2002; 122(1): 84 - 91.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. P. Highcock, I. E. Smith, and J. M. Shneerson
The Effect of Noninvasive Intermittent Positive-Pressure Ventilation During Exercise in Severe Scoliosis*
Chest, May 1, 2002; 121(5): 1555 - 1560.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
F. Thys, G. Liistro, O. Dozin, E. Marion, and D.O. Rodenstein
Determinants of Fi,O2 with oxygen supplementation during noninvasive two-level positive pressure ventilation
Eur. Respir. J., April 1, 2002; 19(4): 653 - 657.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
I. M. STELL, G. PAUL, K. C. LEE, J. PONTE, and J. MOXHAM
Noninvasive Ventilator Triggering in Chronic Obstructive Pulmonary Disease . A Test Lung Comparison
Am. J. Respir. Crit. Care Med., December 1, 2001; 164(11): 2092 - 2097.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M. Wysocki and M. Antonelli
Noninvasive mechanical ventilation in acute hypoxaemic respiratory failure
Eur. Respir. J., July 1, 2001; 18(1): 209 - 220.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
S. MEHTA and N. S. HILL
Noninvasive Ventilation
Am. J. Respir. Crit. Care Med., February 1, 2001; 163(2): 540 - 577.
[Full Text]


Home page
ChestHome page
M.-P. d'Ortho, V. Grillier-Lanoir, P. Levy, F. Goldenberg, E. Corriger, A. Harf, and F. Lofaso
Constant vs Automatic Continuous Positive Airway Pressure Therapy : Home Evaluation
Chest, October 1, 2000; 118(4): 1010 - 1017.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
R. E. Hillberg and D. C. Johnson
Noninvasive Ventilation
N. Engl. J. Med., December 11, 1997; 337(24): 1746 - 1752.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American College of Chest Physicians.