Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shyu, K.-G.
Right arrow Articles by Chen, J.-J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shyu, K.-G.
Right arrow Articles by Chen, J.-J.
(Chest. 1995;108:1201-1205.)
© 1995 American College of Chest Physicians

Diagnostic Accuracy of Transesophageal Echocardiography for Detecting Patent Ductus Arteriosus in Adolescents and Adults

Kou-Gi Shyu MD1; Ling-Ping Lai MD1; Shen-Chang Lin MD1; Hang Chang MD, PhD1; and Jin-Jer Chen MD1

1 From the Department of Emergency Medicine, Shin-Kong, Wu Ho-Su Memorial Hospital, Taipei, and the Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan, Republic of China

To compare the accuracy of transesophageal echocardiography (TEE) with that of transthoracic echocardiography (TTE) in the detection of patent ductus arteriosus (PDA) in the adolescent and the adult, 40 patients with PDA and 50 patients with other congenital heart diseases were studied. All echocardiograms were recorded before cardiac catheterization and surgery. The echocardiographic diagnosis of PDA was made by direct visualization of a shunt flow in the duct. A mosaic flow in the pulmonary artery without direct visualization of the duct was considered possible but not definitely diagnostic of PDA. TEE showed greater sensitivity and negative predictive value than TTE (97% vs 42%, and 98% vs 68%, respectively; p<0.001) in confirming the diagnosis of PDA. The specificity and positive predictive value in establishing the diagnosis of PDA were the same for both techniques. In the subgroup of patients with Eisenmenger's syndrome, the sensitivity of TEE and TTE in confirming diagnosis of PDA was 100% and 12% (p<0.01), respectively. The sensitivity of monoplane and biplane TEE in the diagnosis of PDA was comparable (95% and 100%, respectively; p=NS). In conclusion, TEE was highly sensitive and specific in detecting PDA in adolescents and adults. It was also highly valuable for detecting the cause of pulmonary hypertension in patients with Eisenmenger's syndrome.

Key Words: Eisenmenger's syndrome • patent ductus arteriosus • transesophageal echocardiography • transthoracic echocardiography

Submitted on February 15, 1995
Accepted on May 11, 2007




This article has been cited by other articles:


Home page
ChestHome page
M. S. Plisco, L. M. Lam, and G. M. Matuschak
18-YEAR-OLD WITH HYPOXEMIA AND CHEST PAIN
Chest Meeting Abstracts, October 1, 2005; 128(4): 433S - 434S.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American College of Chest Physicians.