Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kirmse, M.
Right arrow Articles by Hurford, W. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kirmse, M.
Right arrow Articles by Hurford, W. E.
(Chest. 1998;113:1650-1657.)
© 1998 American College of Chest Physicians

Delivery of Inhaled Nitric Oxide Using the Ohmeda INOvent Delivery System

Max Kirmse MD1; Dean Hess PhD, RRT, FCCP1; Yuji Fujino MD1; Robert M. Kacmarek PhD, RRT, FCCP1; and William E. Hurford MD, FCCP1

1 From the Respiratory Care Laboratory and the Department of Anesthesia & Critical Care, Massachusetts General Hospital and Harvard Medical School, Boston

Objectives: We evaluated the Ohmeda INOvent Nitric Oxide Delivery System, which uses an inspiratory flow sensor to inject a synchronized and proportional nitric oxide (NO) flow into the mechanical ventilator circuit. This system should deliver a constant NO concentration independent of ventilator mode, minute ventilation, fraction of inspired oxygen, or ventilator brand. It should also minimize nitrogen dioxide (NO2) formation.

Methods: NO delivery by the INOvent and a premixing NO delivery system were compared using two ventilators (Puritan-Bennett 7200 and Servo 900C). NO concentration was measured within the trachea of an attached lung model using a fast-response chemiluminescence NO analyzer. NO concentration was also measured in the inspiratory limb using the electrochemical analyzer ofthe INOvent. For three NO concentrations (2, 5, and 20 ppm), the ventilators were set for constant flow volume control ventilation, pressure control ventilation, and spontaneous breathing with pressure support ventilation or synchronized intermittent mandatory ventilation. Different tidal volumes (300, 500, 750, and 1,000 mL) and inspiratory times (1 and 2 s) were evaluated. NO2 formation for both ventilators and delivery systems were evaluated at 20 ppm and 95% O2.

Results: Regardless of ventilatory pattern, both systems delivered a constant NO concentration. The error between the target and the delivered NO dose for the INOvent was minus1.3±3.6% with the Puritan-Rennett 7200 and minus3.9±4.3% with the Servo 900C. For the premixing system, the error was minus5.5±4.8% with the Puritan-Rennett 7200 and minus6.7±6.2% with the Servo 900C. NO2 concentrations were 0.5±0.1 ppm during NO delivery by the INOvent, 5.8±1.6 ppm when NO was premixed with air, 0.3±0.1 ppm when NO was premixed with N2.

Conclusion: The INOvent provides a constant NO concentration independent of the ventilatory pattern, and NO2 formation is minimal.

Key Words: critical care • inhaled nitric oxide • mechanical ventilation • nitrogen dioxide

Submitted on September 4, 1997
Accepted on December 2, 1997




This article has been cited by other articles:


Home page
ChestHome page
D. Journois, C. Baufreton, P. Mauriat, P. Pouard, P. Vouhe, and D. Safran
Effects of Inhaled Nitric Oxide Administration on Early Postoperative Mortality in Patients Operated for Correction of Atrioventricular Canal Defects
Chest, November 1, 2005; 128(5): 3537 - 3544.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Lung Cell. Mol. Physiol.Home page
D. C. McCurnin, R. A. Pierce, L. Y. Chang, L. L. Gibson, S. Osborne-Lawrence, B. A. Yoder, J. D. Kerecman, K. H. Albertine, V. T. Winter, J. J. Coalson, et al.
Inhaled NO improves early pulmonary function and modifies lung growth and elastin deposition in a baboon model of neonatal chronic lung disease
Am J Physiol Lung Cell Mol Physiol, March 1, 2005; 288(3): L450 - L459.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
F. Ichinose, J. D. Roberts Jr, and W. M. Zapol
Inhaled Nitric Oxide: A Selective Pulmonary Vasodilator: Current Uses and Therapeutic Potential
Circulation, June 29, 2004; 109(25): 3106 - 3111.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. W. Day, J. A. Hawkins, E. C. McGough, K. L. Crezee, and G. S. Orsmond
Randomized controlled study of inhaled nitric oxide after operation for congenital heart disease
Ann. Thorac. Surg., June 1, 2000; 69(6): 1907 - 1912.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
P. Ceccarelli, L. M. Bigatello, D. Hess, J. Kwo, and L. Melendez
Inhaled Nitric Oxide Delivery by Anesthesia Machines
Anesth. Analg., February 1, 2000; 90(2): 482 - 482.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American College of Chest Physicians.