Chest Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kahn, D. M.
Right arrow Articles by Millman, R. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kahn, D. M.
Right arrow Articles by Millman, R. P.
(Chest. 1998;114:535-540.)
© 1998 American College of Chest Physicians

Identification and Modification of Environmental Noise in an ICU Setting

Douglas M. Kahn DO1; Thorley E. Cook DO1; Carol C. Carlisle RN, AB1; David L. Nelson CRTT1; Naomi R. Kramer MD1; and Richard P. Millman MD, FCCP1

1 From the Division of Pulmonary, Sleep, and Critical Care Medicine, Department of Medicine, Rhode Island Hospital, and Brown University, Providence, Rhode Island

Richard P. Millman, MD, FCCP, Division of Pulmonary, Sleep, and Critical Care Medicine, Rhode Island Hospital, APC 479A, 593 Eddy St, Providence, RI 02903

Study objectives: Noise levels in the hospital setting are exceedingly high, especially in the ICU environment. We set out to determine what caused the noises producing sound peaks ge80 A-weighted decibels (dBA) in our ICU settings, and attempted to reduce the number of sound peaks ge80 dBA through a behavior modification program.

Design: The study was divided into two separate phases: noise identification and a trial of behavior modification. During the noise identification phase we simultaneously recorded sound peaks and the loudest noise heard subjectively by one observer in the medical ICU (MICU) and the respiratory ICU (RICU). During the behavior modification phase of the study we implemented a behavior modification program, geared toward noise reduction, in all of the MICU staff. Sound levels were monitored before and at the end of the behavior modification trial.

Setting: The MICU and RICU of a 720-bed teaching hospital in Providence, RI.

Participants: All ICU staff during the study period.

Interventions: Once the noises that were determined to be amenable to behavior modification were identified, a behavior modification program was conducted during a 3-week period in our MICU. Baseline and post-behavior modification noise recordings were compared in 6-h intervals after sites were matched by number of patients in a room and Acute Physiology and Chronic Health Evaluation II (APACHE II) scores.

Measurements and results: We identified several causes of sound peaks ge80 dBA amenable to behavior modification; television and talking accounted for 49%. We also significantly reduced the 24-h mean peak noise level (p=0.0001), as well as the mean peak noise level (p=0.0001) and the number of sound peaks ge80 dBA (p=0.0001) in all 6-h blocks except for the 12 AM to 6 AM period.

Conclusions: We conclude that many of the noises causing sound peaks ge80 dBA are amenable to behavior modification and that it is possible to reduce the noise levels in an ICU setting significantly through a program of behavior modification.

Key Words: behavior modification • decibel • ICU • noise • sleep

Submitted on March 5, 1997
Accepted on February 5, 1998




This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
J. Y. Gabor, A. B. Cooper, S. A. Crombach, B. Lee, N. Kadikar, H. E. Bettger, and P. J. Hanly
Contribution of the Intensive Care Unit Environment to Sleep Disruption in Mechanically Ventilated Patients and Healthy Subjects
Am. J. Respir. Crit. Care Med., March 1, 2003; 167(5): 708 - 715.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
B. Allaouchiche, F. Duflo, R. Debon, A. Bergeret, and D. Chassard
Noise in the postanaesthesia care unit
Br. J. Anaesth., March 1, 2002; 88(3): 369 - 373.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
N. S. FREEDMAN, J. GAZENDAM, L. LEVAN, A. I. PACK, and R. J. SCHWAB
Abnormal Sleep/Wake Cycles and the Effect of Environmental Noise on Sleep Disruption in the Intensive Care Unit
Am. J. Respir. Crit. Care Med., February 1, 2001; 163(2): 451 - 457.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American College of Chest Physicians.