Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hampson, N. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hampson, N. B.
(Chest. 1998;114:1036-1041.)
© 1998 American College of Chest Physicians

Pulse Oximetry In Severe Carbon Monoxide Poisoning

Neil B. Hampson MD, FCCP1

1 From the Section of Pulmonary and Critical Care Medicine, Virginia Mason Medical Center, Seattle, WA.

Neil B. Hampson, MD, Virginia Mason Clinic C7-PUL, 1100 Ninth Ave, Seattle, WA 98111, email: cidnbh{at}vmmc.org

Study objectives: To evaluate the accuracy and quantitate the error of pulse oximetry measurements of arterial oxygenation in patients with severe carbon monoxide (CO) poisoning.

Design: Retrospective review of patient clinical records.

Setting: Regional referral center for hyperbaric oxygen therapy.

Patients: Thirty patients referred for treatment of acute severe CO poisoning who demonstrated carboxyhemoglobin (COHb) levels >25%, with simultaneous determinations of arterial hemoglobin oxygen saturation by pulse oximetry (SpO2) and arterial blood gas (ABG) techniques.

Measurements and results: COHb levels and measurements of arterial oxygenation from pulse oximetry, ABG analysis, and laboratory CO oximetry were compared. SpO2 did not correlate with COHb levels. SpO2 consistently overestimated the fractional arterial oxygen saturation. The difference between arterial hemoglobin oxygen saturation (SaO2) calculated from ABG analysis and SpO2 increased with increasing COHb level.

Conclusions: Presently available pulse oximeters overestimate arterial oxygenation in patients with severe CO poisoning. An elevated COHb level falsely elevates the SaO2 measurements from pulse oximetry, usually by an amount less than the COHb level, confirming a prior observation in an animal model. Accurate assessment of arterial oxygen content in patients with CO poisoning can currently be performed only by analysis of arterial blood with a laboratory CO-oximetry.

Key Words: carbon monoxide • oxygenation • poisoning • pulse oximetry

Submitted on October 2, 1997
Accepted on April 6, 1998




This article has been cited by other articles:


Home page
Clin. Chem.Home page
S. Haymond, R. Cariappa, C. S. Eby, and M. G. Scott
Laboratory Assessment of Oxygenation in Methemoglobinemia
Clin. Chem., February 1, 2005; 51(2): 434 - 444.
[Abstract] [Full Text] [PDF]


Home page
Biol Res NursHome page
S.-Y. P. Shiao
Functional versus Fractional Oxygen Saturation Readings: Bias and Agreement Using Simulated Solutions and Adult Blood
Biol Res Nurs, April 1, 2002; 3(4): 210 - 221.
[Abstract] [PDF]


Home page
JRSMHome page
I. Blumenthal
Carbon monoxide poisoning
J R Soc Med, January 6, 2001; 94(6): 270 - 272.
[Full Text] [PDF]


Home page
ChestHome page
W. P. Bozeman and N. B. Hampson
Pulse Oximetry in CO Poisoning--Additional Data
Chest, January 1, 2000; 117(1): 295 - 296.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American College of Chest Physicians.