Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jokic, R.
Right arrow Articles by Fitzpatrick, M. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jokic, R.
Right arrow Articles by Fitzpatrick, M. F.
(Chest. 1998;114:1061-1069.)
© 1998 American College of Chest Physicians

Continuous Positive Airway Pressure Requirement During the First Month of Treatment in Patients With Severe Obstructive Sleep Apnea

Ruzica Jokic MD1; Artur Klimaszewski MD1; Guruswamy Sridhar MD2; and Michael F. Fitzpatrick MD1

1 From the Division of Respiratory Medicine, University of Saskatchewan, Saskatoon
2 From the Regina Health District, Regina, Saskatchewan, Canada

Michael F. Fitzpatrick, MD, Division of Respiratory and Critical Care Medicine, Richardson House, Queen's University, Kingston, Ontario, Canada, K7L 3N6; email: mf19{at}post.queensu.ca

Objectives: (1) To compare the continuous positive airway pressure (CPAP) requirement at the time of diagnosis (T0), after 2 weeks (T2), and after 4 weeks (T4) of CPAP treatment, in patients with severe obstructive sleep apnea (OSA); and (2) to assess whether any alteration in CPAP requirement over the first 4 weeks of CPAP treatment would influence daytime alertness, subjective sleepiness, or mood.

Design: A prospective, controlled, single-blind crossover study.

Setting: University teaching hospital.

Patients: Ten patients with newly diagnosed and previously untreated severe OSA (aged 52±9 years, apnea hypopnea index [AHI] of 99±31) and subsequently 10 control patients (aged 52±11 years, AHI 85±17).

Measurements: Overnight polysomnography with CPAP titration to determine the CPAP requirement, which was standardized for body position and sleep stage, on all three occasions (T0, T2, T4). Objective sleep quality, daytime alertness, subjective sleepiness (Epworth Sleepiness Scale), and mood (Hospital Anxiety and Depression Scale).

Results: CPAP requirement decreased from T0 to T2 (median difference, 1.5 cm H2O, 95% confidence interval [CI], 1.1 to 2.7 cm H2O, p=0.0004) and did not differ between T2 and T4. Use of the lower CPAP pressure during T2 to T4 was associated with a decrease in Epworth scale (mean difference, 2.6, 95% CI, 1.2 to 4; p=0.01) and anxiety (median change, 2; 95% CI, 0.5 to 2.9, p=0.03) scores, as compared with the first 2 weeks. Daytime alertness did not differ between T0 to T2 and T2 to T4.

Conclusion: CPAP requirement falls within 2 weeks of starting CPAP treatment. A change to the lower required CPAP was not associated with any deterioration in daytime alertness but was associated with small subjective improvements in sleepiness and mood.

Key Words: CPAP • sleep apnea • treatment

Submitted on December 2, 1997
Accepted on April 1, 1998




This article has been cited by other articles:


Home page
ChestHome page
N. P. Patel, M. Ahmed, and I. Rosen
Split-Night Polysomnography
Chest, November 1, 2007; 132(5): 1664 - 1671.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
R. K. Kakkar and R. B. Berry
Positive Airway Pressure Treatment for Obstructive Sleep Apnea
Chest, September 1, 2007; 132(3): 1057 - 1072.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
C. A. Hukins
Arbitrary-Pressure Continuous Positive Airway Pressure for Obstructive Sleep Apnea Syndrome
Am. J. Respir. Crit. Care Med., March 1, 2005; 171(5): 500 - 505.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
C. A. Massie and R. W. Hart
Clinical Outcomes Related to Interface Type in Patients With Obstructive Sleep Apnea/Hypopnea Syndrome Who Are Using Continuous Positive Airway Pressure
Chest, April 1, 2003; 123(4): 1112 - 1118.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
C. A. Massie, N. McArdle, R. W. Hart, W. W. Schmidt-Nowara, A. Lankford, D. W. Hudgel, N. Gordon, and N. J. Douglas
Comparison between Automatic and Fixed Positive Airway Pressure Therapy in the Home
Am. J. Respir. Crit. Care Med., January 1, 2003; 167(1): 20 - 23.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. S. C. Hui, J. K. W. Chan, D. K. L. Choy, F. W. S. Ko, T. S. T. Li, R. C. C. Leung, and C. K. W. Lai
Effects of Augmented Continuous Positive Airway Pressure Education and Support on Compliance and Outcome in a Chinese Population
Chest, May 1, 2000; 117(5): 1410 - 1416.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American College of Chest Physicians.