Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Srinivasan, S.
Right arrow Articles by Keens, T. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Srinivasan, S.
Right arrow Articles by Keens, T. G.
(Chest. 1998;114:1363-1367.)
© 1998 American College of Chest Physicians

Frequency, Causes, and Outcome of Home Ventilator Failure

Saumini Srinivasan MD1; Sharon M. Doty BSc, CRTT2; Tanya R. White CRTT, RCP2; Victor H. Segura CRTT, RCP2; Mary T. Jansen LVN1; Sally L. Davidson Ward MD1; and Thomas G. Keens MD, FCCP1

1 From the Division of Pediatric Pulmonology, Childrens Hospital Los Angeles, University of Southern California School of Medicine, Los Angeles, CA
2 From the Greater Los Angeles Branch, NMC Homecare, Pasadena, CA.

Thomas G. Keens, MD, Division of Pediatric Pulmonology, Childrens Hospital Los Angeles, 4650 Sunset Blvd, MS No. 83, Los Angeles, CA 90027; e-mail: keens{at}chla.usc.edu

Study objectives: The safety of home ventilators has been questioned. We collected data to study the following: frequency of home ventilator failure, apparent causes for the failure or malfunc ¬ tion, and adverse consequences following the failure.

Study design: Information on all requests to correct home ventilator failures reported to a home respiratory equipment vendor was collected prospectively between November 1991, and November 1992.

Patients: There were 150 ventilator-assisted patients aged 2 to 77 years; 44 were le 18 years. They received 841,234 h of home mechanical ventilation (average, 15.4 h/d per ventilator-assisted patient).

Results: There were 189 reports of home ventilator failure. Defective equipment or mechanical failure was found in only 39% (73 reports), equivalent to one home ventilator failure for every 1.25 years of continuous use. Other causes of ventilator failure included the following: improper care, damage, or tampering with the ventilator by caregivers (13%), functional equipment improperly used by caregivers (30%), and equipment functional but the patient's condition changed, mimicking ventilator failure (3%). No problem could be identified in 16%. The following actions were required: ventilator replacement (44%), repair of a defective part (6%), replacement of a functioning ventilator for psychological comfort (14%), ventilator adjustments made (21%), caregiver reeducation (7%), caregiver anxiety or distress reduced (3%), and no action required (4%). Hospitalization was required only in two cases (1%). No adverse outcomes, deaths, or serious injuries were associated with home ventilator failure.

Conclusions: We conclude that in 150 patients requiring home mechanical ventilation, ventilator failure occurred relatively infrequently, and there were no adverse outcomes as a result of equipment failure at home. We speculate that equipment failure is not a frequent or serious problem for ventilator-assisted patients treated at home.

Key Words: assisted ventilation • backup ventilator • home mechanical ventilation • ventilator failure

Submitted on December 16, 1997
Accepted on March 31, 1998




This article has been cited by other articles:


Home page
ThoraxHome page
A K Simonds
Risk management of the home ventilator dependent patient
Thorax, May 1, 2006; 61(5): 369 - 371.
[Full Text] [PDF]


Home page
ThoraxHome page
R Farre, D Navajas, E Prats, S Marti, R Guell, J M Montserrat, C Tebe, and J Escarrabill
Performance of mechanical ventilators at the patient's home: a multicentre quality control study
Thorax, May 1, 2006; 61(5): 400 - 404.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
R. Farre, S. J. Lloyd-Owen, N. Ambrosino, G. Donaldson, J. Escarrabill, B. Fauroux, D. Robert, B. Schoenhofer, A. Simonds, and J. A. Wedzicha
Quality control of equipment in home mechanical ventilation: a European survey
Eur. Respir. J., July 1, 2005; 26(1): 86 - 94.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
S. Karakurt, F. Fanfulla, and S. Nava
Is It Safe for Patients With Chronic Hypercapnic Respiratory Failure Undergoing Home Noninvasive Ventilation To Discontinue Ventilation Briefly?
Chest, May 1, 2001; 119(5): 1379 - 1386.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American College of Chest Physicians.