Chest Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (14)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kress, J. P.
Right arrow Articles by Hall, J. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kress, J. P.
Right arrow Articles by Hall, J. B.
(Chest. 1999;115:1316-1320.)
© 1999 American College of Chest Physicians

Determination of Hemoglobin Saturation in Patients With Acute Sickle Chest Syndrome*

A Comparison of Arterial Blood Gases and Pulse Oximetry

John P. Kress, MD; Anne S. Pohlman, RN, MSN and Jesse B. Hall, MD

* From the Department of Medicine, University of Chicago, Chicago, IL.

Correspondence to: Jesse B. Hall, MD, Section of Pulmonary and Critical Care Medicine, MC 6026, University of Chicago, 5841 S Maryland Ave, Chicago, IL 60637; e-mail: jhall{at}medicine.bsd.uchicago.edu

Study objectives: To evaluate three different methods of measuring oxygen saturation in patients suffering from acute sickle chest syndrome.

Design: A prospective, descriptive study of 9 months' duration.

Setting: A tertiary care university hospital.

Patients: Adult patients with acute sickle chest syndrome scheduled to undergo RBC exchange transfusion.

Interventions: None.

Measurements: Baseline hemoglobin oxygen saturation was determined simultaneously by (1) calculation based on PaO2 and an oxyhemoglobin dissociation curve algorithm, (2) co-oximetry, and (3) pulse oximetry. These same measures were repeated after exchange transfusion. Baseline and postexchange hemoglobin electrophoresis was performed in all patients.

Results: Baseline calculated saturation overestimated true saturation (determined by co-oximetry) with a baseline mean bias (co-oximetry minus calculated saturation) of -6.78 ± 2.63% (95% confidence interval for bias: -8.37% to -5.19%). Pulse oximetry was not different than co-oximetry at baseline with a baseline bias of +1.86 ± 3.25% (95% confidence interval: -0.1% to 3.82%). After exchange transfusion, there was no bias between either co-oximetry and calculated saturation (mean difference: -0.17 ± 1.31% [95% confidence interval: -0.95% to 0.61%]), or co-oximetry and pulse oximetry (mean difference: +0.3 ± 1.53% [95% confidence interval: -0.62% to 1.22%]).

Conclusions: Calculated saturation overestimates true saturation during acute sickle chest syndrome. This discrepancy abates after exchange transfusion. Pulse oximetry more closely follows co-oximetry than does calculated saturation during acute sickle chest syndrome.

Key Words: arterial blood gas • co-oximetry • exchange transfusion • oxygen dissociation curve • pulse oximetry • sickle cell anemia




This article has been cited by other articles:


Home page
Postgrad. Med. J.Home page
A K Siddiqui and S Ahmed
Pulmonary manifestations of sickle cell disease
Postgrad. Med. J., July 1, 2003; 79(933): 384 - 390.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American College of Chest Physicians.