Chest ACCP Career Connection
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (13)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McKone, E. F.
Right arrow Articles by Gallagher, C. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McKone, E. F.
Right arrow Articles by Gallagher, C. G.
(Chest. 1999;116:363-368.)
© 1999 American College of Chest Physicians

Reproducibility of Maximal Exercise Ergometer Testing in Patients With Cystic Fibrosis*

E. F. McKone, MD; S. C. Barry, BPhysio; M. X. FitzGerald, MD, FCCP and C. G. Gallagher, MD, FCCP

* From the National Adult Cystic Fibrosis Unit, Department of Respiratory Medicine, St. Vincent's University Hospital, Dublin, Ireland.

Correspondence to: C. G. Gallagher, MD, FCCP, Department of Respiratory Medicine, St. Vincent's University Hospital, Dublin 4, Republic of Ireland; e-mail: cgall{at}indigo.ie

Objectives: Exercise testing in patients with cystic fibrosis (CF) has become an important tool in assessing disease severity and predicting overall outcome. The reproducibility of maximal exercise testing was examined in adult subjects with stable CF.

Methods: Nine subjects with CF underwent a total of three maximal exercise tests carried out under identical circumstances over a 28-day period. Oxygen uptake (O2), minute ventilation (E), respiratory frequency (f), heart rate (HR), and arterial oxygen saturation (SaO2) were measured at rest, at end exercise, and at 40% and 70% of maximum workload.

Results: There were no significant differences in these measurements among the three tests. Reproducibility of exercise performance was assessed using the coefficient of variation. The mean within-subject coefficient of variation for test variables at end exercise are as follows: O2, 6.9%; E, 6.2%; f, 5.8%; HR, 3.0%; and SaO2, 1.1%. The mean within-subject coefficient of variation for test variables at 40% and 70% of maximal work rates are as follows: O2, 5.2% and 4.6%; SaO2, 0.3% and 0.9%; HR, 4.0% and 3%; E, 5.7% and 6.5%; and f, 5.8% and 7.2%, respectively.

Conclusions: Variables measured during clinical cycle ergometer exercise testing in adult patients with stable CF are reproducible. No learning effect was found on repeated testing.

Key Words: cystic fibrosis • exercise testing • reproducibility




This article has been cited by other articles:


Home page
RadiologyHome page
J. D. Dodd, S. C. Barry, R. B. M. Barry, C. G. Gallagher, S. J. Skehan, and J. B. Masterson
Thin-Section CT in Patients with Cystic Fibrosis: Correlation with Peak Exercise Capacity and Body Mass Index.
Radiology, July 1, 2006; 240(1): 236 - 245.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
E. F. McKone, S. C. Barry, M. X. FitzGerald, and C. G. Gallagher
Role of arterial hypoxemia and pulmonary mechanics in exercise limitation in adults with cystic fibrosis
J Appl Physiol, September 1, 2005; 99(3): 1012 - 1018.
[Abstract] [Full Text] [PDF]


Home page
Psychosom. Med.Home page
P. I. Parekh, J. A. Blumenthal, M. A. Babyak, R. LaCaille, S. Rowe, L. Dancel, R. M. Carney, R. D. Davis, S. Palmer, and for the INSPIRE Investigators
Gas Exchange and Exercise Capacity Affect Neurocognitive Performance in Patients With Lung Disease
Psychosom Med, May 1, 2005; 67(3): 425 - 432.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. E. Hansen, X.-G. Sun, Y. Yasunobu, R. P. Garafano, G. Gates, R. J. Barst, and K. Wasserman
Reproducibility of Cardiopulmonary Exercise Measurements in Patients With Pulmonary Arterial Hypertension
Chest, September 1, 2004; 126(3): 816 - 824.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
A. G. Thin, S. J. Linnane, E. F. McKone, R. Freaney, M. X. FitzGerald, C. G. Gallagher, and P. McLoughlin
Use of the Gas Exchange Threshold to Noninvasively Determine the Lactate Threshold in Patients With Cystic Fibrosis*
Chest, June 1, 2002; 121(6): 1761 - 1770.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
H. Blau, H. Mussaffi-Georgy, G. Fink, C. Kaye, A. Szeinberg, S. A. Spitzer, and J. Yahav
Effects of an Intensive 4-Week Summer Camp on Cystic Fibrosis* : Pulmonary Function, Exercise Tolerance, and Nutrition
Chest, April 1, 2002; 121(4): 1117 - 1122.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American College of Chest Physicians.