Chest ACCP Career Connection
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brand, P.
Right arrow Articles by Häußinger, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brand, P.
Right arrow Articles by Häußinger, K.
(Chest. 1999;116:543-548.)
© 1999 American College of Chest Physicians

Aerosol-Derived Airway Morphometry and Aerosol Bolus Dispersion in Patients With Lung Fibrosis and Lung Emphysema*

Peter Brand, PhD; Martin Kohlhäufl, MD; Thomas Meyer, MD; Titus Selzer; Joachim Heyder, PhD and Karl Häußinger, MD

* From the Clinical Research Group "Aerosols in Medicine" of the GSF National Research Center for Environment and Health, Institute for Inhalation Biology and the Clinic for Respiratory Medicine, Gauting, Germany.

Correspondence to: Peter Brand, PhD, GSF, Institute for Inhalation Biology, Robert-Koch-Allee 6, D-82131 Gauting, Germany; e-mail: BRAND{at}GSF.DE

Objective: Patients with lung emphysema show increased aerosol-derived dimensions of peripheral airspaces and increased aerosol bolus dispersion (AD). To apply these tests in epidemiologic studies, the objective of this pilot study was to investigate whether morphometric changes caused by lung fibrosis can be distinguished from those caused by emphysema.

Design: This study was designed as a cross-sectional study in which airspace dimensions and AD in patients with emphysema and in patients with fibrosis were compared. Forty patients participated in the study: 20 patients had high-resolution CT (HRCT)-proved lung emphysema and 20 patients had HRCT-proved lung fibrosis. All patients underwent conventional lung function tests, aerosol-derived airway morphometry (ADAM), and AD measurements.

Results: Patients with lung emphysema showed normal dimensions of small airways but enlarged airspace dimensions in the lung periphery. Patients with fibrosis showed in all lung depths increased airspace dimensions. AD was increased in patients with emphysema but was normal in patients with fibrosis.

Conclusions: These results show that when using ADAM and AD, morphometric changes caused by emphysema can be distinguished from those caused by fibrosis with high sensitivity and specificity.

Key Words: convective gas mixing • lung emphysema • lung fibrosis • lung morphometry