Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (107)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cochrane, M. G.
Right arrow Articles by Ben-Joseph, R. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cochrane, M. G.
Right arrow Articles by Ben-Joseph, R. H.
(Chest. 2000;117:542-550.)
© 2000 American College of Chest Physicians

Inhaled Corticosteroids for Asthma Therapy*

Patient Compliance, Devices, and Inhalation Technique

Mac G. Cochrane, MD; Mohan V. Bala, PhD; Kristen E. Downs, MSPH; Josephine Mauskopf, PhD and Rami H. Ben-Joseph, PhD

* From Guy’s Hospital (Dr. Cochrane), London, UK; Centocor, Inc. (Dr. Bala), Malvern, PA; Research Triangle Institute (Ms. Downs and Dr. Mauskopf), Research Triangle Park, NC; and Merck & Co (Dr. Ben-Joseph), Whitehouse Station, NJ.

Correspondence to: Josephine A. Mauskopf, PhD, Research Triangle Institute, 3040 Cornwallis Rd, Box 12194, Research Triangle Park, NC 27709; e-mail: jom{at}rti.com

Background: Patient compliance, inhalation devices, and inhalation techniques influence the effectiveness of inhaled medications.

Methods: This article presents the results of a systematic literature review of studies measuring compliance with inhaled corticosteroids, measuring inhalation technique with different inhalation devices, and estimating the proportion of inhaled drug that is deposited in the lung.

Results:Overall, patients took the recommended doses of inhaled medication on 20 to 73% of days. Frequency of efficient inhalation technique ranged from 46 to 59% of patients. Education programs have been shown to improve compliance and inhalation techniques. The lung deposition achieved with different inhalers depends on particle size as well as inhaler technique.

Conclusion: This review demonstrates that multiple factors may come between a prescription of an inhaled corticosteroid and the arrival of that medicine at its target organ, the lung.

Key Words: asthma • compliance • inhaler technique • inhalers




This article has been cited by other articles:


Home page
The Annals of PharmacotherapyHome page
S. M Gawchik
Successful Treatment of Previously Uncontrolled Adult Asthma with Budesonide Inhalation Suspension: Five-Year Case Histories
Ann. Pharmacother., October 1, 2007; 41(10): 1728 - 1733.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G. K. Crompton
Inhaler technique blind spot.
Eur. Respir. J., May 1, 2006; 27(5): 1070 - 1071.
[Full Text] [PDF]


Home page
ChestHome page
G. K. Crompton, P. J. Barnes, M. B. Dolovich, R. C. Ahrens, D. R. Hess, P. Anderson, R. Dhand, J. L. Rau, G. C. Smaldone, and G. Guyatt
Aerosol Delivery Devices
Chest, May 1, 2006; 129(5): 1388 - 1389.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. W. Pijnenburg, E. M. Bakker, W. C. Hop, and J. C. De Jongste
Titrating Steroids on Exhaled Nitric Oxide in Children with Asthma: A Randomized Controlled Trial
Am. J. Respir. Crit. Care Med., October 1, 2005; 172(7): 831 - 836.
[Abstract] [Full Text] [PDF]


Home page
CMAJHome page
Inhalation devices
Can. Med. Assoc. J., September 13, 2005; 173(6_suppl): S39 - S45.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
D. N. R. Payne and A. Bush
"Refractory" Eosinophilic Airway Inflammation in Severe Asthma
Am. J. Respir. Crit. Care Med., December 15, 2004; 170(12): 1385 - 1385.
[Full Text] [PDF]


Home page
Proc Am Thorac SocHome page
J. Winkler, G. Hochhaus, and H. Derendorf
How the Lung Handles Drugs: Pharmacokinetics and Pharmacodynamics of Inhaled Corticosteroids
Proceedings of the ATS, December 1, 2004; 1(4): 356 - 363.
[Abstract] [Full Text] [PDF]


Home page
Proc Am Thorac SocHome page
G. Hochhaus
New Developments in Corticosteroids
Proceedings of the ATS, November 1, 2004; 1(3): 269 - 274.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
B. K. Rubin
What Does It Mean When a Patient Says, "My Asthma Medication Is Not Working?"
Chest, September 1, 2004; 126(3): 972 - 981.
[Full Text] [PDF]


Home page
The Annals of PharmacotherapyHome page
S. R Erickson, A. Chang, C. E Johnson, and L. D Gruppen
Lecture Versus Web Tutorial for Pharmacy Students' Learning of MDI Technique
Ann. Pharmacother., April 1, 2003; 37(4): 500 - 505.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
L. M. Pinto Pereira, Y. Clement, C. K. Da Silva, D. McIntosh, and D. T. Simeon
Understanding and Use of Inhaler Medication by Asthmatics in Specialty Care in Trinidad* : A Study Following Development of Caribbean Guidelines for Asthma Management and Prevention
Chest, June 1, 2002; 121(6): 1833 - 1840.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
P. Bergquist and G.K. Crompton
Clinical management of asthma in 1999: the Asthma Insights and Reality in Europe (AIRE) study
Eur. Respir. J., July 1, 2001; 18(1): 248 - 248.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American College of Chest Physicians.