Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (12)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Giannini, D.
Right arrow Articles by Paggiaro, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Giannini, D.
Right arrow Articles by Paggiaro, P.
(Chest. 2000;117:1319-1323.)
© 2000 American College of Chest Physicians

The Protective Effect of Salbutamol Inhaled Using Different Devices on Methacholine Bronchoconstriction*

Daniele Giannini, MD; Antonella Di Franco, MD; Elena Bacci, MD; Federico Lorenzo Dente, MD, FCCP; Mauro Taccola, MD; Barbara Vagaggini, MD and Pierluigi Paggiaro, MD

* From the Cardio-Thoracic Department, University of Pisa, Pisa, Italy.

Correspondence to: Daniele Giannini, MD, U.O. Fisiopatologia Respiratoria, Ospedale di Cisanello, via Paradisa 2, 56100 Pisa, Italy

Study objective: To determine the protective effect of salbutamol, 100 µg, inhaled by different devices (pressurized metered-dose inhaler [pMDI; Ventolin; GlaxoWellcome; Greenford, UK], pMDI + spacer [Volumatic; GlaxoWellcome], or breath-activated pMDI [Autohaler; 3M Pharmaceuticals; St. Paul, MN]) on bronchoconstriction induced by methacholine.

Design: Randomized, double-blind, cross-over, placebo-controlled study.

Patients: Eighteen subjects with stable, moderate asthma, asymptomatic, receiving regular treatment with salmeterol, 50 µg bid, and inhaled beclomethasone dipropionate, 250 µg bid, in the last 6 months, with high hyperreactivity to methacholine (baseline provocative dose of methacholine causing a 20% fall in FEV1 [PD20] geometric mean [GM], 0.071 mg). Subjects were classified into two groups: subjects with incorrect (n = 5) pMDI inhalation technique, and subjects with correct (n = 13) inhalation technique.

Methods and measurements: After cessation of therapy for 3 days, all subjects underwent four methacholine challenge tests, each test 1 week apart, each time 15 min after inhalation of salbutamol, 100 µg (via pMDI, pMDI + spacer, or Autohaler), or placebo. The protective effect on methacholine challenge test was evaluated as the change in the PD20, and expressed in terms of doubling doses of methacholine in comparison with placebo treatment.

Results: The PD20 was significantly higher after salbutamol inhalation than after placebo inhalation, but no significant difference was observed among the three different inhalation techniques. Only when salbutamol was inhaled via pMDI + spacer, PD20 was slightly but not significantly higher (pMDI GM, 0.454 mg; pMDI + spacer GM, 0.559 mg; and Autohaler GM, 0.372 mg; not significant [NS]) than other inhalation techniques. Similar results (mean ±SEM) were obtained with doubling doses of methacholine (pMDI, 2 ± 0.47; pMDI + spacer, 3 ± 0.35; and Autohaler, 2.4 ± 0.40; NS). No significant difference was found among techniques when subjects with correct or incorrect inhalation technique were separately considered.

Conclusions: Our data show that the protective effect of salbutamol, 100 µg, on methacholine-induced bronchoconstriction is not affected by the different inhalation techniques, although inhalation via pMDI + spacer tends to improve the bronchoprotective ability of salbutamol. These data confirm the clinical efficacy of salbutamol, whatever the device, and the patient’s inhalation technique.

Key Words: inhalation devices • methacholine challenge test • salbutamol




This article has been cited by other articles:


Home page
BMJHome page
F. S F Ram, J. Wright, D. Brocklebank, and J. E S White
Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering beta 2 agonists bronchodilators in asthma
BMJ, October 20, 2001; 323(7318): 901 - 901.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American College of Chest Physicians.