Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (16)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Laube, B. L.
Right arrow Articles by Zeitlin, P. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Laube, B. L.
Right arrow Articles by Zeitlin, P. L.
(Chest. 2000;118:1069-1076.)
© 2000 American College of Chest Physicians

Targeting Aerosol Deposition in Patients With Cystic Fibrosis*

Effects of Alterations in Particle Size and Inspiratory Flow Rate

Beth L. Laube, PhD; Rajkumari Jashnani, PhD; Richard N. Dalby, PhD and Pamela L. Zeitlin, MD, PhD, FCCP

* From the Johns Hopkins Medical Institutions (Drs. Laube and Zeitlin), and the University of Maryland (Drs. Jashnani and Dalby), Baltimore, MD.

Correspondence to: Beth L. Laube, PhD, Johns Hopkins Hospital, Park 316, 600 North Wolfe St, Baltimore, MD 21287-2533; e-mail: blaube{at}welchlink.welch.jhu.edu

Study objective: To determine if aerosolized medications can be targeted to deposit in the smaller, peripheral airways or the larger, central airways of adult cystic fibrosis (CF) patients by varying particle size and inspiratory flow rate.

Design: Randomized clinical trial.

Setting: Outpatient research laboratory.

Patients: Nine adult patients with CF.

Interventions: Patients inhaled an aerosol comprised of 3.68 ± 0.04 µm saline solution droplets (two visits) or 1.01 ± 0.2 µm saline solution droplets (two visits) for 30 s, starting from functional residual capacity and breathing at a slow or faster inspiratory flow rate. On all visits, the saline solution was admixed with the radioisotope 99mTc. Immediately after inhalation, a gamma camera recorded the deposition pattern of the radioaerosol in the lungs. Deposition images were analyzed in terms of the inner:outer zone (I:O) ratio, a measure of deposition in an inner zone (large, central airways) vs an outer zone (small airways and alveoli).

Measurements and results: For the 3.68-µm aerosol, I:O ratios averaged 2.29 ± 1.45 and 2.54 ± 1.48 (p > 0.05), indicating that aerosol distribution within the lungs was unchanged while breathing at 12 ± 2 L/min vs 31 ± 5 L/min, respectively. For the 1.01-µm aerosol, I:O ratios averaged 2.09 ± 0.96 and 3.19 ± 1.95 (p < 0.05), indicating that deposition was predominantly in the smaller airways while breathing at 18 ± 5 L/min and in the larger airways while breathing at 38 ± 8 L/min, respectively.

Conclusions: These results suggest that the targeted delivery of an aerosol to the smaller, peripheral airways or the larger, central airways of adult CF patients may be achieved by generating an aerosol comprised of approximately 1.0-µm particles and inspiring from functional residual capacity at approximately 18 L/min and ~ 38 L/min, respectively.

Key Words: aerosols • cystic fibrosis • gene therapy • inspiratory flow rate • particle size




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
O. S. Usmani, M. F. Biddiscombe, J. A. Nightingale, S. R. Underwood, and P. J. Barnes
Effects of bronchodilator particle size in asthmatic patients using monodisperse aerosols
J Appl Physiol, November 1, 2003; 95(5): 2106 - 2112.