Study objectives: To compare two different image registration methods for accurately displaying the position of a flexible bronchoscope on a previously acquired three-dimensional CT scan during bronchoscopy.
Setting: Bronchoscopy suite of a university hospital.
Patients: Fifteen adult patients scheduled for nonemergent bronchoscopy.
Methods: A miniature electromagnetic position sensor was placed at the tip of a flexible bronchoscope. Previously acquired three-dimensional CT scans were registered with the patient in the bronchoscopy suite. Registration method 1 used multiple skin fiducial markers. Registration method 2 used the inner surface of the trachea itself for registration. Method 1 was objectively assessed by measuring the error distance between the real skin marker position and the computer display position. Methods 1 and 2 were subjectively assessed by the bronchoscopist correlating visual bronchoscopic anatomic location with the computer display position on the CT image.
Results: The error distance (± SD) from known points for registration method 1 was 5.6 ± 2.7 mm. Objective error distances were not measured for method 2 because no accurate placement of the bronchoscope sensor could be correlated with CT position. Subjectively, method 2 was judged more accurate than method 1 when compared with the fiberoptic view of the airways through the bronchoscope. Additionally, method 2 had the advantage of not requiring placement of fiducial markers before the CT scan. Respiratory motion contributed an error of 3.6 ± 2.6 mm, which was partially compensated for by a second tracking sensor placed on the patients chest.
Conclusion: Image registration method 2 of surface fitting the trachea rather than method 1 of fiducial markers was subjectively judged to be superior for registering the position of a flexible bronchoscope during bronchoscopy. Method 2 was also more practical inasmuch as no special CT scanning technique was required before bronchoscopy.
Key Words: bronchoscopy computers CT image-guided surgery stereotaxy
This article has been cited by other articles:
![]() |
Y. Schwarz, J. Greif, H. D. Becker, A. Ernst, and A. Mehta Real-Time Electromagnetic Navigation Bronchoscopy to Peripheral Lung Lesions Using Overlaid CT Images: The First Human Study. Chest, April 1, 2006; 129(4): 988 - 994. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Sra, D. Krum, A. Malloy, M. Vass, B. Belanger, E. Soubelet, R. Vaillant, and M. Akhtar Registration of Three-Dimensional Left Atrial Computed Tomographic Images With Projection Images Obtained Using Fluoroscopy Circulation, December 13, 2005; 112(24): 3763 - 3768. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Hautmann, A. Schneider, T. Pinkau, F. Peltz, and H. Feussner Electromagnetic Catheter Navigation During Bronchoscopy: Validation of a Novel Method by Conventional Fluoroscopy Chest, July 1, 2005; 128(1): 382 - 387. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Dickfeld, H. Calkins, M. Zviman, R. Kato, G. Meininger, L. Lickfett, R. Berger, H. Halperin, and S. B. Solomon Anatomic Stereotactic Catheter Ablation on Three-Dimensional Magnetic Resonance Images in Real Time Circulation, November 11, 2003; 108(19): 2407 - 2413. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |