Objective: To identify potential risk factors for the need for an additional cold or heated humidifier in nasal continuous positive airway pressure (nCPAP) circuitry.
Design: A prospective cohort study.
Setting: University hospital sleep-disorders center.
Patients: Eighty-two consecutive patients with obstructive sleep apnea syndrome were followed up for a median of 347 days (range, 3 to 530 days) after the initiation of nCPAP therapy.
Measurements and results: In 46 patients (56%), the occurrence of upper-airway symptoms led to the addition of a cold humidifier after a median time of 39 days (range, 2 to 94 days). In 23 of the 46 patients, the persistence of the symptoms indicated the secondary use of a heated humidifier after a median time of 28 days (range, 5 to 70 days). nCPAP use (mean ± SD) was not influenced by cold humidification (4.58 ± 2.05 h/d vs 4.7 ± 2.48 h/d; p = 0.75), but it increased significantly with heated humidification (5.38 ± 2.26 h/d vs 3.51 ± 2.53 h/d; p < 0.01). Anthropometric characteristics, drying medications, clinical findings such as deformity of the nasal septum, symptoms of a chronic mucosa disease (CMD), a previous uvulopalatopharyngoplasty (UPPP), and polysomnographic parameters had no significant effect on the need for a cold humidifier. Age > 60 years (odds ratio [OR], 5.58; 95% confidence interval [CI], 1.69 to 18.43), drying medications (OR, 6.59; 95% CI, 1.29 to 33.51), presence of CMD (OR, 4.11; 95% CI, 1.24 to 13.58), and previous UPPP (OR, 4.56; 95% CI, 1.18 to 17.6) were found as significant risk factors for the addition of a heated humidifier.
Conclusion: Our results demonstrate that heated humidification significantly improves the nCPAP daily rate of use and that its need may be predicted.
Key Words: humidification nasal continuous positive airway pressure obstructive sleep apnea syndrome
This article has been cited by other articles:
![]() |
M. Duong, L. Jayaram, D. Camfferman, P. Catcheside, I. Mykytyn, and R. D. McEvoy Use of heated humidification during nasal CPAP titration in obstructive sleep apnoea syndrome Eur. Respir. J., October 1, 2005; 26(4): 679 - 685. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Mador, M. Krauza, A. Pervez, D. Pierce, and M. Braun Effect of Heated Humidification on Compliance and Quality of Life in Patients With Sleep Apnea Using Nasal Continuous Positive Airway Pressure Chest, October 1, 2005; 128(4): 2151 - 2158. [Abstract] [Full Text] [PDF] |
||||
![]() |
P Gordon and M H Sanders Sleep {middle dot} 7: Positive airway pressure therapy for obstructive sleep apnoea/hypopnoea syndrome Thorax, January 1, 2005; 60(1): 68 - 75. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Gagnadoux, X.L. Nguyen, D. Rakotonanahary, S. Vidal, and B. Fleury Wrist-actigraphic estimation of sleep time under nCPAP treatment in sleep apnoea patients Eur. Respir. J., June 1, 2004; 23(6): 891 - 895. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Fleury, D. Rakotonanahary, B. Petelle, G. Vincent, N. P. Fleury, B. Meyer, and B. Lebeau Mandibular Advancement Titration for Obstructive Sleep Apnea: Optimization of the Procedure by Combining Clinical and Oximetric Parameters Chest, May 1, 2004; 125(5): 1761 - 1767. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.M. Neill, H.S. Wai, S.P.T. Bannan, C.R. Beasley, M. Weatherall, and A.J. Campbell Humidified nasal continuous positive airway pressure in obstructive sleep apnoea Eur. Respir. J., August 1, 2003; 22(2): 258 - 262. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |