Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (6)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nguyen, T. T.
Right arrow Articles by Bommer, W. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nguyen, T. T.
Right arrow Articles by Bommer, W. J.
(Chest. 2001;120:1287-1292.)
© 2001 American College of Chest Physicians

Contrast Microbubbles Improve Diagnostic Yield in ICU Patients With Poor Echocardiographic Windows*

Thanh T. Nguyen, DO; Milind R. Dhond, MD; Raju Sabapathy, MD and William J. Bommer, MD

* From the University of California, Davis Medical Center, Sacramento, CA.

Correspondence to: William J, Bommer, MD, Division of Cardiovascular Medicine, Ambulatory Care Center, 4860 Y St, Suite 2800, Sacramento, CA 95817

Objective: To determine the value of contrast echocardiographic studies in patients admitted to ICUs who have poor echocardiographic windows secondary to COPD, ventilator use, or inability to obtain optimal positioning for the echocardiogram.

Design: A prospective comparison study of technically difficult patients in the ICU.

Outcome measure: The total scores for the left ventricle (LV) in the two-chamber and four-chamber views were calculated at baseline and following injection of 1 to 2 mL of a contrast agent. The mean numbers of segments visualized in all patients at baseline and after injection of contrast agent were compared to assess the effect on improved visualization.

Results: Forty consecutive patients underwent echocardiography in the ICU for evaluation of LV function. Of these, 25 patients (63%) had poor visualization of the endocardium and required IV contrast agent. In these 25 patients, the average baseline segmental score was 4.5, compared to 11.6 in patients who received an IV contrast agent. Nineteen patients had an average baseline segmental score of 3.9 and were deemed to have a nondiagnostic study. After administration of IV contrast, all patients converted to a diagnostic study, with an average score of 11.6 segments visualized.

Conclusions: Use of echocardiographic contrast agents in selected patients with poor baseline echocardiographic windows in the ICU setting significantly enhances segmental LV visualization and yielded 100% conversion from nondiagnostic to diagnostic studies.

Key Words: contrast agent • echocardiogram • ICU • IV




This article has been cited by other articles:


Home page
ChestHome page
Y. Beaulieu and P. E. Marik
Bedside Ultrasonography in the ICU: Part 1
Chest, August 1, 2005; 128(2): 881 - 895.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American College of Chest Physicians.