Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (11)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brenner, M.
Right arrow Articles by Milliken, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brenner, M.
Right arrow Articles by Milliken, J.
(Chest. 2002;121:201-209.)
© 2002 American College of Chest Physicians

Effects of a Novel Implantable Elastomer Device for Lung Volume Reduction Surgery in a Rabbit Model of Elastase-Induced Emphysema*

Matthew Brenner, MD, FCCP; Xavier Gonzalez, MD; Blanding Jones, MD; Rick Ha, BS; Kathryn Osann, PhD; Robert McKenna, MD and Jeffrey Milliken, MD

* From the Pulmonary and Critical Care Medicine Division (Dr. Brenner), Departments of Surgery (Drs. Jones and Milliken), University of California Irvine Medical Center, Orange, CA; Cedars Sinai Medical Center (Dr. McKenna); Los Angeles, CA; Spiration Inc., (Dr. Gonzalez), Redmond, WA; and the Beckman Laser Institute and Medical Clinic (Mr. Ha and Dr. Osann), Irvine, CA.

Correspondence to: Matthew Brenner, MD, FCCP, Pulmonary and Critical Care Division, University of California Irvine Medical Center, 101 City Dr South, Orange, CA 92868-3298

Objectives: There is intense interest in lung volume reduction surgery (LVRS) for treatment of severe symptomatic emphysema. LVRS results in objective and subjective improvement in lung function in selected patients. However, LVRS is complicated by substantial morbidity, including prolonged pulmonary air leak associated with resection of emphysematous lung tissue. In this study, we investigated the use of a novel implanted silicone elastomer device that reduces lung volume without surgical resection, in a previously reported emphysematous animal model. The purpose of this investigation was to determine the applicability, physiologic effects, complications, and air-leak results of this lung volume reducer (LVR) approach. Design: Controlled, randomized, prospective animal study. Emphysema was induced in 20 New Zealand white rabbits with three nebulizations of 10,000 U of porcine elastase. After 6 weeks, the animals were randomized to control sham surgery (n = 10) vs implanted silicone elastomer LVR (n = 10) treatment groups. Lung function, including helium-dilution lung volumes, static respiratory system compliance curves, and diffusion capacity of the lung for carbon monoxide (DLCO), was measured at baseline, following emphysema induction (week 6), and when the animals were killed (1 week after LVR or sham surgery). Histologic evaluation was performed in all lung specimens after fixation. Results: Moderate emphysema developed after elastase nebulization, assessed by lung function and postmortem histology. Functional residual capacity (FRC) and an upward shift of lung compliance curves was observed with development of emphysema at 6 weeks (p < 0.05). Following LVR, FRC decreased (p = 0.005) and compliance curves shifted back downward (p = 0.002), without reduction in DLCO. There was no change in control sham animals. DLCO did not change in either group. Conclusions: In this short-term, randomized, controlled animal model study, the implantable LVR approach produced safe and effective lung volume reduction without tissue resection in the treated animals. The implant procedure produced minimal morbidity, no mortality, and no observed air-leak complications in the treated animals. Limitations include the short-term follow-up and moderate degree of emphysema in this animal model. Further research is required to assess long-term effects and complications of this method for lung volume reduction.

Key Words: air leak • lung volume reducer • lung volume reduction surgery • silicon




This article has been cited by other articles:


Home page
ImagingHome page
N J Screaton and T Koh
Emphysema and smoking-related lung diseases
Imaging, October 1, 2004; 16(1): 50 - 60.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. Brenner, N. M. Hanna, R. Mina-Araghi, A. F. Gelb, R. J. McKenna Jr, and H. Colt
Innovative Approaches to Lung Volume Reduction for Emphysema
Chest, July 1, 2004; 126(1): 238 - 248.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
S. N. Mink, X. Gonzalez, K. Duke, E. Bautista, and L. Tan
Lung Volume Reduction Surgery in Canine Model of Predominantly Upper Lobe Emphysema: Advantages of New Surgical System
Chest, February 1, 2004; 125(2): 633 - 643.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
R. A. Maxfield
New and Emerging Minimally Invasive Techniques for Lung Volume Reduction
Chest, February 1, 2004; 125(2): 777 - 783.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M. Decramer
Treatment of chronic respiratory failure: lung volume reduction surgery versus rehabilitation
Eur. Respir. J., November 16, 2003; 22(47_suppl): 47S - 56s.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
American Thoracic Society/European Respiratory Society Statement: Standards for the Diagnosis and Management of Individuals with Alpha-1 Antitrypsin Deficiency
Am. J. Respir. Crit. Care Med., October 1, 2003; 168(7): 818 - 900.
[Full Text] [PDF]


Home page
ChestHome page
P. E. Munro, M. J. Bailey, J. A. Smith, and G. I. Snell
Lung Volume Reduction Surgery in Australia and New Zealand: Six Years On: Registry Report
Chest, October 1, 2003; 124(4): 1443 - 1450.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
G. I. Snell, L. Holsworth, Z. L. Borrill, K. R. Thomson, V. Kalff, J. A. Smith, and T. J. Williams
The Potential for Bronchoscopic Lung Volume Reduction Using Bronchial Prostheses: A Pilot Study
Chest, September 1, 2003; 124(3): 1073 - 1080.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American College of Chest Physicians.