Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by El-Khatib, M. F.
Right arrow Articles by Obeid, M. Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by El-Khatib, M. F.
Right arrow Articles by Obeid, M. Y.
(Chest. 2002;121:475-479.)
© 2002 American College of Chest Physicians

Effect of Continuous Positive Airway Pressure on the Rapid Shallow Breathing Index in Patients Following Cardiac Surgery*

Mohamad F. El-Khatib, PhD; Ghassan W. Jamaleddine, MD, FCCP; Andre R. Khoury, RN and Mounir Y. Obeid, MD

* From the Departments of Anesthesiology (Dr. El-Khatib and Mr. Khoury), Medicine (Dr. Jamaleddine), and Surgery (Dr. Obeid), School of Medicine, American University of Beirut, Beirut, Lebanon.

Correspondence to: Mohamad F. El-Khatib, PhD, American University of Beirut, PO Box 11–0236, Riad El Solh, Beirut 1107 2020, Lebanon; e-mail: mk05{at}aub.edu.lb

Objectives: To compare the rapid shallow breathing index (RSBI) under different ventilatory support settings prior to extubation trials.

Design: Prospective study.

Setting: Cardiac surgery unit at a university hospital.

Patients: A total of 33 coronary artery bypass grafting patients ready for extubation.

Interventions: Enrolled patients received a continuous positive airway pressure (CPAP) trial of 5 cm H2O and fraction of inspired oxygen (FIO2) of 40% (condition 1), a CPAP trial of 5 cmH2O and FIO2 of 21% (condition 2), and a 1-min spontaneously breathing room air trial without ventilatory support (condition 3). These trials were applied in random order.

Measurements and main results: Average values of respiratory frequency and tidal volume were measured under the three experimental conditions in all patients immediately prior to extubation. The RSBIs were determined for each patient under each condition; the average RSBIs under conditions 1, 2, and 3 were compared for significance. The average RSBIs (± SD) were significantly smaller under condition 1 (34 ± 13) and condition 2 (36 ± 14) compared to condition 3 (71 ± 24). There was no significant difference in RSBI between conditions 1 and 2.

Conclusions: The administration of 5 cm H2O of CPAP can influence the determination of the RSBI. In contrast, changes in FIO2 have no effect on RSBI determination. We speculate that using the RSBI during CPAP may mislead the clinician into premature discontinuation of mechanical ventilation. Consequently, different threshold values for the RSBI should be derived for different ventilatory support levels.

Key Words: continuous positive airway pressure • coronary artery bypass grafting • mechanical ventilation • rapid shallow breathing index




This article has been cited by other articles:


Home page
ChestHome page
B. P. Krieger and M. Campos
Weaning Parameters: Read the Methodology Before Proceeding
Chest, December 1, 2002; 122(6): 1873 - 1874.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American College of Chest Physicians.