Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (12)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kelley, A.
Right arrow Articles by Brown, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kelley, A.
Right arrow Articles by Brown, R.
(Chest. 2003;123:725-730.)
© 2003 American College of Chest Physicians

Spirometry Testing Standards in Spinal Cord Injury*

Alyson Kelley, BS; Eric Garshick, MD, MOH, FCCP; Erica R. Gross, BS; Steven L. Lieberman, MD; Carlos G. Tun, MD and Robert Brown, MD{dagger}

* From the Pulmonary and Critical Care Medicine Section, Medical Service, and Rehabilitation Medicine Service, VA Boston Healthcare System; Harvard Medical School, Boston, MA. {dagger} Currently at Massachusetts General Hospital.

Correspondence to: Eric Garshick, MD, MOH, FCCP, Pulmonary and Critical Care Medicine Section, VA Boston Healthcare System, 1400 VFW Parkway, West Roxbury, MA 02132; e-mail: eric.garshick{at}med.va.gov

Study objectives: Because muscle paralysis makes it uncertain whether subjects with spinal cord injury (SCI) can perform spirometry in accordance with American Thoracic Society (ATS) standards, determinants of test failure were examined.

Design: Cross-sectional study.

Setting: Veterans Affairs (VA) medical center.

Participants: Veterans with SCI at VA Boston Healthcare System and nonveterans recruited by mail and advertisement.

Measurements and results: Two hundred thirty of 278 subjects (83%) were able to produce three expiratory efforts lasting >= 6 s and without excessive back-extrapolated volume (EBEV). In 217 of 230 subjects (94%), FVC and FEV1 were each reproducible in accordance with 1994 ATS standards. In the remaining 48 subjects, efforts with smooth and continuous volume-time tracings and acceptable flow-volume loops were identified. These subjects had a lower percentage of predicted FVC, FEV1, and maximum expiratory and inspiratory pressures compared to the others, and a greater proportion had neurologically complete cervical injury (42% compared to 16%). In 19 subjects (40%), some expiratory efforts were not sustained maximally for >= 6 s but had at least a 0.5-s plateau at residual volume (short efforts). In eight subjects (17%), some efforts were not short but had EBEV. In the remaining 21 subjects (44%), some efforts were short, some had EBEV, and some had both. If these efforts were not rejected, 262 of 278 subjects (94%) would have produced three acceptable efforts, and in 257 subjects (92%), the efforts were reproducible.

Conclusions: Subjects with SCI with the most impaired respiratory muscles and abnormal pulmonary function are able to perform spirometry reproducibly despite not meeting usual ATS acceptability standards. Exclusion of these subjects would lead to bias in studies of respiratory function in SCI. The modification of spirometry testing standards to include efforts with EBEV and with a 0.5-s plateau if < 6 s would reduce the potential for bias.

Key Words: reference standards • spinal cord injury • spirometry




This article has been cited by other articles:


Home page
Eur Respir JHome page
M. Akpinar-Elci, K. B. Fedan, and P. L. Enright
FEV6 as a surrogate for FVC in detecting airways obstruction and restriction in the workplace
Eur. Respir. J., February 1, 2006; 27(2): 374 - 377.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American College of Chest Physicians.