Chest ACCP Career Connection
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Heard, S. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heard, S. O.
(Chest. 2003;123:469S-474S.)
© 2003 American College of Chest Physicians

Gastric Tonometry*

The Hemodynamic Monitor of Choice (Pro)

Stephen O. Heard, MD, FCCP

* From the University of Massachusetts Medical School, Worcester, MA.

Correspondence to: Stephen O. Heard, MD, FCCP, Department of Anesthesiology, 55 Lake Ave North, University of Massachusetts Medical School, Worcester, MA 01655; e-mail: stephen. heard{at}umassmed.edu

Controversy exists as to the best means to monitor the critically ill patient and the appropriate end points of therapy. Use of global hemodynamic or metabolic parameters may be normal in the patient who has not been completely or adequately resuscitated. Decreased perfusion to the gut is not well tolerated and may contribute to the development of the multiple organ dysfunction syndrome. Gastric tonometry is a minimally invasive way to monitor splanchnic perfusion in the critically ill patient. Data suggest that tonometry is useful for outcome prognostication and for detection of early hypovolemia. In addition, use of gastric intramucosal pH or mucosal-arterial CO2 gap as end points of resuscitation may be superior to other conventional whole-body parameters. For these reasons, gastric tonometry must be considered the hemodynamic monitor of choice.

Key Words: gastric tonometry • hemodynamic • hypoperfusion • hypovolemia




This article has been cited by other articles:


Home page
Arch SurgHome page
M. J. Martin, E. FitzSullivan, A. Salim, T. V. Berne, and S. Towfigh
Use of Serum Bicarbonate Measurement in Place of Arterial Base Deficit in the Surgical Intensive Care Unit
Arch Surg, August 1, 2005; 140(8): 745 - 751.
[Abstract] [Full Text] [PDF]


Home page
Biol Res NursHome page
E. M. Fisher, M. E. Kerr, L. A. Hoffman, R. P. Steiner, and R. A. Baranek
A Comparison of Gastric and Rectal CO2 in Cardiac Surgery Patients
Biol Res Nurs, April 1, 2005; 6(4): 268 - 280.
[Abstract] [PDF]


Home page
Canadian J. AnesthesiaHome page
M. Weiss, A. Gerber, and A. Dullenkopf
Nitrous oxide does not affect automated air tonometry in children: [Le protoxyde d'azote n'agit pas sur la tonometrie a l'air, automatisee, chez les enfants]
Can J Anesth, November 1, 2003; 50(9): 930 - 932.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American College of Chest Physicians.