Chest Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Reuthebuch, O.
Right arrow Articles by Turina, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reuthebuch, O.
Right arrow Articles by Turina, M.
(Chest. 2004;125:418-424.)
© 2004 American College of Chest Physicians

Novadaq SPY*

Intraoperative Quality Assessment in Off-Pump Coronary Artery Bypass Grafting

Oliver Reuthebuch, MD; Achim Häussler, MD; Michele Genoni, MD; Reza Tavakoli, MD; Dragan Odavic, MD; Alexander Kadner, MD and Marko Turina, MD

* From the Clinic for Cardiovascular Surgery (Drs. Reuthebuch, Häussler, Kadner, and Turina), University Hospital Zürich, and Clinic for Cardiac Surgery (Drs. Genoni, Tavakoli, and Odavic), Zürich, Switzerland.

Correspondence to: Oliver Reuthebuch, MD, Clinic for Cardiovascular Surgery, University Hospital Zürich, Rämistrasse 100, CH-8091 Zürich, Switzerland; e-mail: oliver.reuthebuch{at}chi.usz.ch

Objectives: Off-pump coronary artery bypass grafting may decrease operative morbidity when compared to on-pump bypass grafting; however, it is technically demanding and thus quality control is essential. This study assesses the clinical feasibility of a new, indocyanine green (ICG)-based imaging system (SPY; Novadaq Technologies; Toronto, ON, Canada) to monitor the quality of anastomoses and grafts in off-pump revascularization.

Setting: Thirty-eight consecutive patients undergoing nonemergent coronary artery bypass grafting without the use of extracorporeal circulation at two Swiss cardiac surgery clinics were included. On completion of bypass grafts, the quality of the grafts was assessed using the ICG-based imaging system. The imaging device comprises an 806-nm laser light source that is used to cause ICG to fluoresce and a near infrared-sensitive charged couple device videocamera that is used to capture the fluorescence images. ICG was administered through the central venous line, and images were acquired during the first pass of the ICG through the field of view. Graft flow (qualitative) and the quality of the grafts and anastomoses were assessed intraoperatively.

Results: Between March 2002 and September 2002, a total of 38 patients (26 men and 12 women; mean ± SD age, 64.6 ± 10.5 years; body mass index, 27.1 ± 2.9) underwent surgery and imaging at two institutions. One hundred seven of 124 grafts (45 arteries and 62 veins) were analyzed. Seventeen grafts could not be assessed due to difficulties in positioning. The imaging system was easy to handle, and no adverse reactions to ICG were observed. Four of the 107 grafts imaged required revision (three anastomotic constrictions and one graft dissection). Each imaging sequence required approximately 1.25 to 2.5 mg of ICG. The images were equivalent to angiography without the need for radiographs and catheter insertion. In addition, the course of coronaries that would otherwise be difficult to locate in obese patients could be detected using the imaging system. Biochemical and ECG data demonstrated an absence of intraoperative or postoperative myocardial damage, and no liver enzyme elevation or renal dysfunction.

Conclusions: This study supports the clinical utility of a ICG-based imaging system for the assessment of the quality of bypass grafts, which appears to be safe and simple to use.

Key Words: angiography • beating heart • cardiac surgery • coronary artery bypass • indocyanine green • minimally invasive




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
H. Stein, J. M. Smith, J. R. Robinson, and M. R. Katz
Target vessel detection and coronary anastomosis assessment by intraoperative 12-MHz ultrasound.
Ann. Thorac. Surg., September 1, 2006; 82(3): 1078 - 1084.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
N. D. Desai, S. Miwa, D. Kodama, G. Cohen, G. T. Christakis, B. S. Goldman, M. O. Baerlocher, M. P. Pelletier, and S. E. Fremes
Improving the Quality of Coronary Bypass Surgery With Intraoperative Angiography: Validation of a New Technique
J. Am. Coll. Cardiol., October 18, 2005; 46(8): 1521 - 1525.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. P.J. Budde, R. Meijer, T. C. Dessing, C. Borst, and P. F. Grundeman
Detection of construction errors in ex vivo coronary artery anastomoses by 13-MHz epicardial ultrasonography
J. Thorac. Cardiovasc. Surg., May 1, 2005; 129(5): 1078 - 1083.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
H. B. Ward and R. F. Kelly
OPCAB vs CABG: Who, What, When, Where?
Chest, March 1, 2004; 125(3): 815 - 816.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American College of Chest Physicians.