Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (17)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cotter, G.
Right arrow Articles by Vered, Z.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cotter, G.
Right arrow Articles by Vered, Z.
(Chest. 2004;125:1431-1440.)
© 2004 American College of Chest Physicians

Accurate, Noninvasive Continuous Monitoring of Cardiac Output by Whole-Body Electrical Bioimpedance*

Gad Cotter, MD; Yaron Moshkovitz, MD; Edo Kaluski, MD; Amram J. Cohen, MD, FCCP; Hilton Miller, MD{dagger}; Daniel Goor, MD and Zvi Vered, MD

* From the Cardiology Department (Drs. Cotter, Kaluski, and Vered), Assaf–Harofeh Medical Center, Zerifin; the Cardiac Surgery Department (Drs. Moshkovitz and Goor), Sackler School of Medicine, Tel Aviv University, Tel Aviv; the Department of Cardiology (Dr. Miller), Sourasky Medical Center, Tel-Aviv; and the Department of Cardiac Surgery (Dr. Miller), the Edith Wolfson Medical Center, Holon, Israel.

Study objectives: Cardiac output (CO) is measured but sparingly due to limitations in its measurement technique (ie, right-heart catheterization). Yet, in recent years it has been suggested that CO may be of value in the diagnosis, risk stratification, and treatment titration of cardiac patients, especially those with congestive heart failure (CHF). We examine the use of a new noninvasive, continuous whole-body bioimpedance system (NICaS; NI Medical; Hod-Hasharon, Israel) for measuring CO. The aim of the present study was to test the validity of this noninvasive cardiac output system/monitor (NICO) in a cohort of cardiac patients.

Design: Prospective, double-blind comparison of the NICO and thermodilution CO determinations.

Patients: We enrolled 122 patients in three different groups: during cardiac catheterization (n = 40); before, during, and after coronary bypass surgery (n = 51); and while being treated for acute congestive heart failure (CHF) exacerbation (n = 31).

Measurements and intervention: In all patients, CO measurements were obtained by two independent blinded operators. CO was measured by both techniques three times, and an average was determined for each time point. CO was measured at one time point in patients undergoing coronary catheterization; before, during, and after bypass surgery in patients undergoing coronary bypass surgery; and before and during vasodilator treatment in patients treated for acute heart failure.

Results: Overall, 418 paired CO measurements were obtained. The overall correlation between the NICO cardiac index (CI) and the thermodilution CI was r = 0.886, with a small bias (0.0009 ± 0.684 L) [mean ± 2 SD], and this finding was consistent within each group of patients. Thermodilution readings were 15% higher than NICO when CI was < 1.5 L/min/m2, and 5% lower than NICO when CI was > 3 L/min/m2. The NICO has also accurately detected CI changes during coronary bypass operation and vasodilator administration for acute CHF.

Conclusion: The results of the present study indicate that whole-body bioimpedance CO measurements obtained by the NICO are accurate in rapid, noninvasive measurement and the follow-up of CO in a wide range of cardiac clinical situations.

Key Words: cardiac function test • cardiac output • congestive heart failure




This article has been cited by other articles:


Home page
Eur Heart JHome page
Y. Hasin, N. Danchin, G. S. Filippatos, M. Heras, U. Janssens, J. Leor, M. Nahir, A. Parkhomenko, K. Thygesen, M. Tubaro, et al.
Recommendations for the structure, organization, and operation of intensive cardiac care units
Eur. Heart J., August 2, 2005; 26(16): 1676 - 1682.
[Abstract] [Full Text] [PDF]