Chest ACCP Career Connection
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yamagami, T.
Right arrow Articles by Nishimura, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yamagami, T.
Right arrow Articles by Nishimura, T.
(Chest. 2004;126:744-747.)
© 2004 American College of Chest Physicians

Percutaneous Needle Biopsy for Small Lung Nodules Beneath the Rib Under CT Scan Fluoroscopic Guidance With Gantry Tilt*

Takuji Yamagami, MD, PhD; Takeharu Kato, MD; Shigeharu Iida, MD; Tatsuya Hirota, MD and Tsunehiko Nishimura, MD, PhD

* From the Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.

Correspondence to: Takuji Yamagami, MD, PhD, Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, 465 Kajii-chyo, Kawaramachi-Hirokoji, Kamigyo, Kyoto, 602-8566, Japan; e-mail yamagami{at}koto.kpu-m.ac.jp

Objectives: The present study was performed to evaluate the efficacy and safety of gantry tilting for the performance of lung biopsy of peripheral small lesions located beneath the rib.

Design: Interventional.

Materials and methods: Our study was based on 22 of 237 lesions for which percutaneous needle biopsies of the lung were performed under CT scan-fluoroscopic guidance at our institution between January 2000 and August 2002. For these 22 lesions, a biopsy was performed with gantry tilt because a rib blocked the biopsy route even after trials to change the relationship between the target and the rib. The characteristics of each lesion, the success rate for obtaining an adequate specimen, and the ability to determine whether the lesion was malignant or benign were investigated, specific cell types were characterized, and the complications that were encountered were identified.

Results: In all 22 lesions, adequate specimens for cytopathologic evaluation were obtained using fine-needle aspiration biopsy, tissue core biopsies, or both. In 21 lesions, whether the lesion was malignant or benign was precisely diagnosed, and in 19 lesions the specific cell type was determined. No serious complications occurred.

Conclusion: Percutaneous needle biopsy under CT scan-fluoroscopic guidance with gantry tilt is a useful and safe technique for the biopsy of small lung nodules located beneath the rib.

Key Words: biopsies • CT guidance • lung biopsy • technology