Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Frutos-Vivar, F.
Right arrow Articles by Anzueto, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Frutos-Vivar, F.
Right arrow Articles by Anzueto, A.
(Chest. 2006;130:1664-1671.)
© 2006 American College of Chest Physicians

Risk Factors for Extubation Failure in Patients Following a Successful Spontaneous Breathing Trial*

Fernando Frutos-Vivar, MD; Niall D. Ferguson, MD, MSc; Andrés Esteban, MD, PhD; Scott K. Epstein, MD, FCCP; Yaseen Arabi, MD, FCCP; Carlos Apezteguía, MD; Marco González, MD; Nicholas S. Hill, MD, FCCP; Stefano Nava, MD; Gabriel D’Empaire, MD and Antonio Anzueto, MD

* From the Hospital Universitario de Getafe (Drs. Frutos-Vivar and Esteban), Madrid, Spain; the Department of Medicine (Dr. Ferguson), Division of Respirology, and the Interdepartmental Division of Critical Care Medicine, University Health Network, University of Toronto, Toronto, ON, Canada; the Department of Medicine (Dr. Epstein), Caritas-St. Elizabeth’s Medical Center, Tufts University School of Medicine, Boston, MA; King Abdulaziz Medical City (Dr. Arabi), Riyadh, Saudi Arabia; Hospital Profesor Posadas (Dr. Apezteguía), Buenos Aires, Argentina; Hospital General de Medellín (Dr. González), Medellín, Colombia; Pulmonary and Critical Care Division (Dr. Hill), Department of Medicine, New England Medical Center, Tufts University School of Medicine, Boston, MA; Respiratory Intensive Care Unit (Dr. Nava), Fondazione S. Maugeri, Istituto Scientifico di Pavia, Pavia, Italy; Hospital de Clínicas (Dr. D’Empaire), Caracas, Venezuela; and South Texas Veterans Health Care System (Dr. Anzueto), San Antonio, TX.

Correspondence to: Fernando Frutos-Vivar, MD, Intensive Care Unit, Hospital Universitario de Getafe, Carretera de Toledo km 12,500, 28905 Getafe, Madrid, Spain; e-mail: ffrutos{at}ucigetafe.com

Abstract

Background: To assess the factors associated with reintubation in patients who had successfully passed a spontaneous breathing trial.

Methods: We used logistic regression and recursive partitioning analyses of prospectively collected clinical data from adults admitted to ICUs of 37 hospitals in eight countries, who had undergone invasive mechanical ventilation for > 48 h and were deemed ready for extubation.

Results: Extubation failure occurred in 121 of the 900 patients (13.4%). The logistic regression analysis identified the following associations with reintubation: rapid shallow breathing index (RSBI) [odds ratio (OR), 1.009 per unit; 95% confidence interval (CI), 1.003 to 1.015]; positive fluid balance (OR, 1.70; 95% CI, 1.15 to 2.53); and pneumonia as the reason for initiating mechanical ventilation (OR, 1.77; 95% CI, 1.10 to 2.84). The recursive partitioning analysis allowed the separation of patients into different risk groups for extubation failure: (1) RSBI of > 57 breaths/L/min and positive fluid balance (OR, 3.0; 95% CI, 1.8 to 4.8); (2) RSBI of < 57 breaths/L/min and pneumonia as reason for mechanical ventilation (OR, 2.0; 95% CI, 1.1 to 3.6); (3) RSBI of > 57 breaths/L/min and negative fluid balance (OR, 1.4; 95% CI, 0.8 to 2.5); and (4) RSBI of < 57 breaths/L/min (OR, 1 [reference value]).

Conclusions: Among routinely measured clinical variables, RSBI, positive fluid balance 24 h prior to extubation, and pneumonia at the initiation of ventilation were the best predictors of extubation failure. However, the combined predictive ability of these variables was weak.

Key Words: artificial respiration • extubation • predictive index • reintubation • ventilator weaning




This article has been cited by other articles:


Home page
ChestHome page
J. R. Bach
Risk Factors for Extubation Success in Patients Following Failure of a Spontaneous Breathing Trial
Chest, May 1, 2007; 131(5): 1615 - 1615.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American College of Chest Physicians.