Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
doi:10.1378/chest.06-2216
(Chest. 2007; 131:432-438)
© 2007 American College of Chest Physicians
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bathoorn, E.
Right arrow Articles by Kerstjens, H. A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bathoorn, E.
Right arrow Articles by Kerstjens, H. A. M.

Safety of Sputum Induction During Exacerbations of COPD*

Erik Bathoorn, MD; Jeroen Liesker, MD; Dirkje Postma, MD, PhD; Gerard Koëter, MD, PhD; Antoon J. M. van Oosterhout, PhD and Huib A. M. Kerstjens, MD, PhD

* From the Department of Pulmonology (Drs. Bathoorn, Liesker, Postma, Koëter, and Kerstjens) and Laboratory of Allergology and Pulmonary Diseases (Dr. van Oosterhout), Groningen Research Institute for Asthma and COPD, University Medical Center Groningen, University of Groningen, the Netherlands.

Correspondence to: Huib A. M. Kerstjens, MD, PhD, Department of Pulmonology, University Medical Center Groningen, Postbox 30001, 9700RB, Groningen, the Netherlands; e-mail: h.a.m.kerstjens{at}int.umcg.nl

Abstract

Sputum induction (SI) is considered to be a safe tool for assessing airway inflammation in stable patients with COPD, but little is known about its safety during exacerbations. We therefore assessed the safety of SI during COPD exacerbations. SI data from 44 COPD patients were assessed both in the stable phase and during exacerbation. The median FEV1 for the stable phase and exacerbation were 61% predicted (interquartile range [IQR], 49 to 74% predicted) and 51% predicted (IQR, 45 to 60% predicted), respectively. The median decrease in FEV1 with SI during an exacerbation was 0.27 L (IQR, 0.17 to 0.40 L) vs 0.28 L (IQR, 0.22 to 0.44 L) during the stable phase (p = 0.03). The patients experienced the associated dyspnea well; no other adverse events occurred. All FEV1 values returned to within 90% of their initial value within 30 min. A larger decrease in FEV1 due to SI during an exacerbation was associated with the following parameters in the stable phase of disease: lower total sputum cell count (r = –0.37; p = 0.01); higher percentage of eosinophils (r = 0.33; p = 0.04); and a larger decrease in FEV1 after SI (r = 0.39; p = 0.03). In a multivariate analysis, the only independent association was with the larger decrease in FEV1 in the stable phase. We concluded that SI can be safely carried out in patients with mild-to-moderate COPD who experience an exacerbation, and this occurs with no greater risk than in stable patients with COPD.

Key Words: COPD • exacerbation • safety • sputum induction







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American College of Chest Physicians.