Chest Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
doi:10.1378/chest.06-2964
(Chest. 2007; 131:1783-1787)
© 2007 American College of Chest Physicians
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Piet, A. H.M.
Right arrow Articles by Senan, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piet, A. H.M.
Right arrow Articles by Senan, S.

Can Mediastinal Nodal Mobility Explain the Low Yield Rates for Transbronchial Needle Aspiration Without Real-Time Imaging?*

Anna H.M. Piet, MD; Frank J. Lagerwaard, MD, PhD; Peter W.A. Kunst, MD, PhD; John R. van Sörnsen de Koste, PhD; Ben J. Slotman, MD, PhD and Suresh Senan, PhD

* From the Department of Radiation Oncology (Dr. Piet), Academic Medical Center, Amsterdam, the Netherlands; and the Departments of Radiation Oncology (Drs. Lagerwaard, van Sörnsen de Koste, Slotman, and Senan) and Pulmonary Diseases (Dr. Kunst), VU University Medical Center, Amsterdam, the Netherlands.

Correspondence to: Frank J. Lagerwaard, MD, PhD, Department of Radiation Oncology, VU University Medical Center, De Boelelaan 1117, 1007 MB Amsterdam, the Netherlands; e-mail: fj.lagerwaard{at}vumc.nl

Abstract

Background: The diagnostic yields with transbronchial needle aspiration (TBNA) for mediastinal nodes are highly variable. Nodal positions, as assessed on a breath-hold conventional CT scan, do not account for nodal motion. We studied nodal motion on four-dimensional (4D) CT scans.

Methods: A total of 47 mediastinal nodes were identified on 4D CT scans performed for radiotherapy planning in 25 patients with lung cancer. Nodes were mainly located at stations 4R, 4L, 7, and 2R, and each identified node was contoured in all 10 phases of the 4D CT scan. Nodal motion was correlated with changes in carina position.

Results: The mean (± SD) nodal diameter was 10.2 ± 4.0 mm; and the mean nodal volume was 1.8 ± 2.3 mL. Movement was maximal in the craniocaudal axis (mean length, 4.7 ± 2.3 mm), and the corresponding mean mediolateral and ventrodorsal movements were 2.8 ± 1.9 mm and 2.4 ± 1.8 mm, respectively. The mean three-dimensional displacement of the nodal center was 6.2 ± 2.9 mm, and it exceeded 10 mm in five nodes. The nodal mass was constantly present in only 25 ± 14% of the region encompassing all nodal positions. The mean variation in craniocaudal distance between all nodes and the carina position during respiration was 5.3 ± 2.1 mm (range, 2.2 to 10.5 mm).

Conclusions: Both nodal motion and the varying distance between the carina and nodal position may explain the lower diagnostic yields for TBNA procedures performed without real-time guidance.

Key Words: lung cancer • lymph node motion • staging • transbronchial needle aspiration







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American College of Chest Physicians.