Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
doi:10.1378/chest.07-0073
(Chest. 2007; 132:2020-2029)
© 2007 American College of Chest Physicians
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Pinsky, M. R.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pinsky, M. R.

Hemodynamic Evaluation and Monitoring in the ICU*

Michael R. Pinsky, MD, FCCP

* From the Department of Critical Care Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA.

Correspondence to: Michael R. Pinsky, MD, FCCP, 606 Scaife Hall, 3550 Terrace St, Pittsburgh, PA 15213; e-mail: pinskymr{at}upmc.edu

Abstract

Hemodynamic monitoring, a cornerstone in the management of the critically ill patient, is used to identify cardiovascular insufficiency, its probable cause, and response to therapy. Still it is difficult to document the efficacy of monitoring because no device improves outcome unless coupled to a treatment that improves outcome. Several clinical trials have consistently documented that preoptimization for high-risk surgery patients treated in the operating room and early (< 12 h) goal-directed resuscitation in septic patients treated in the emergency department reduce morbidity, mortality, and resource use (costs) when the end points of resuscitation were focused on surrogate measures of adequacy of global oxygen delivery (DO2). The closer the resuscitation is to the insult, the greater the benefit. When resuscitation was started after ICU admission in high-risk surgical patients, reduced length of stay was also seen. The focus of these monitoring protocols is to establish a mean arterial pressure > 65 mm Hg and then to increase DO2 to 600 mL/min/m2 within the first few minutes to hours of presentation. To accomplish these goals, hemodynamic monitoring focuses more on measures of cardiac output and mixed venous oxygen saturation to access adequacy of resuscitation efforts than on filling pressures. Although these protocols reduce mortality and morbidity is selected high-risk patient groups, the widespread use of monitoring-driven treatment protocols has not yet happened, presumably because all studies have been single-center trials using a single, proprietary blood flow-monitoring device. Multicenter trials are needed of early goal-directed therapies for all patients presenting in shock of various etiologies and when the protocol and not the monitoring device is the primary variable.

Key Words: blood-flow monitoring • goal-directed therapy • hemodynamic monitoring • ICU







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American College of Chest Physicians.