Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by GOTT, V. L.
Right arrow Articles by LILLEHEI, C. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by GOTT, V. L.
Right arrow Articles by LILLEHEI, C. W.
(Chest. 1957;32:615-625.)
© 1957 American College of Chest Physicians

A Disposable Unitized Plastic Sheet Oxygenator for Open Heart Surgery

VINCENT L. GOTT M.D.1; ROBERT D. SELLERS M.D.1; RICHARD A. DeWALL M.D.2; RICHARD L. VARCO M.D., F.C.C.P.1; and C. WALTON LILLEHEI M.D., F.C.C.P.1

1 The Department of Surgery and Variety Club Heart Hospital, University of Minnesota Medical School, Minneapolis.
2 The Department of Surgery and Variety Club Heart Hospital, University of Minnesota Medical School, Minneapolis., Research Fellow, American Heart Association.

1. A unitized, disposable, inexpensive bubble diffusion oxygenator constructed of two sheets of polyvinyl plastic has been used successfully in 11 clinical cases.

2. This oxygenator is commercially available as a sterile packaged unit ready to hang up, prime, and use.

3. Seven of 11 patients had intracardiac defects completely corrected and are living and well at this time. The remaining four patients (three were seriously ill infants) succumbed from complications including pulmonary hypertension and complete atrio-ventricular heart block. In none of these four patients did it appear that the performance of the pump or oxygenator could be incriminated in the unsuccessful outcome.

4. Biochemical perfusion data on these 11 patients compares favorably with determinations made on 250 patients perfused with the three dimensional prototype of this unit.