Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Froelicher, V. F.
Right arrow Articles by Lancaster, M. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Froelicher, V. F., Jr.
Right arrow Articles by Lancaster, M. C.
(Chest. 1974;65:512-517.)
© 1974 American College of Chest Physicians

A Comparison of the Reproducibility and Physiologic Response to Three Maximal Treadmill Exercise Protocols

Victor F. Froelicher Jr. Maj., MC, USAF1; Homer Brammell M.D.1; Garland Davis M.S.1; Ignacio Noguera B.S.1; Alderus Stewart M.S.1; and Malcolm C. Lancaster Col., MC, USAF1

1 Clinical Sciences Division, USAF School of Aerospace Medicine, Brooks Air Force Base, Texas

Fifteen volunteers performed the Bruce, Balke, and Taylor maximal treadmill exercise protocols. Each protocol was performed by each subject three times, one test a week for nine weeks. Maximal and submaximal oxygen consumption and heart rate were determined. Statistical analyses revealed: (1) a greater mean maximal oxygen consumption with the Taylor protocol; (2) no difference in reproducibility of the measurement of maximal oxygen consumption among the three protocols; (3) an increase in mean maximal treadmill time without an increase in mean maximal oxygen consumption with treadmill experience; and (4) a decrease in submaximal oxygen consumption and heart rate at similar workloads with treadmill experience. A wide range of maximal oxygen consumption was found for any particular maximal treadmill time. Because of these findings, the clinical use of treadmill time to determine maximal oxygen consumption or functional aerobic impairment or changes in these parameters should be critically reinvestigated.

Submitted on October 31, 1974
Accepted on December 27, 1974




This article has been cited by other articles:


Home page
CirculationHome page
P. A. Ades, M. L. Waldmann, W. L. Meyer, K. A. Brown, E. T. Poehlman, W. W. Pendlebury, K. O. Leslie, P. R. Gray, R. R. Lew, and M. M. LeWinter
Skeletal Muscle and Cardiovascular Adaptations to Exercise Conditioning in Older Coronary Patients
Circulation, August 1, 1996; 94(3): 323 - 330.
[Abstract] [Full Text]


Home page
CirculationHome page
I. L. Pina, G. J. Balady, P. Hanson, A. J. Labovitz, D. W. Madonna, and J. Myers
Guidelines for Clinical Exercise Testing Laboratories : A Statement for Healthcare Professionals From the Committee on Exercise and Cardiac Rehabilitation, American Heart Association
Circulation, February 1, 1995; 91(3): 912 - 921.