Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fishbein, M. C.
Right arrow Articles by Roberts, W. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fishbein, M. C.
Right arrow Articles by Roberts, W. C.

Chest, Vol 68, 6-11, Copyright © 1975 by American College of Chest Physicians


ARTICLES

Late postoperative anatomic observations after insertion of Hufnagel caged-ball prostheses in descending thoracic aorta

MC Fishbein and WC Roberts

Clinical and necropsy observations are described in two patients who died 11 and 13 years, respectively, after implantation of Hufnagel prostheses (the first ever used successfully in humans to treat cardiac valve disease) in descending thoracic aorta. Despite the long implantation periods, there was no evidence of prosthetic degeneration or thrombosis or intravascular hemolysis. Although approximately 4000 Hufnagel descending aortic prostheses were distributed by the manufacturer for human use, data in only 55 patients in whom these prostheses were inserted were found in previous publications, and 26 of them had died. Of the 13 late deaths previously reported, no evidence of prosthetic degeneration or thrombosis was described in the three patients surviving greater than 3 years (8, 10, 12.5 years, respectively). Since neither our patients nor any of the other three reported long-term survivors had prosthetic-related complications and since the dangers of excising the descending aortic prosthesis are considerable, it appears most reasonable, as a rule, not to remove the descending aortic prosthesis at any time in these patients if aortic valve replacement is subsequently performed.


This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
R. W. Emery, T. Carrel, R. K. Wolf, M. J. Slepian, and K. S. Tweden
Description and evaluation of a ventriculo-coronary artery bypass device that provides bi-directional coronary flow
Eur. J. Cardiothorac. Surg., January 1, 2004; 25(1): 43 - 50.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L.A. van Herwerden and P.W. Serruys
Percutaneous valve implantation: back to the future?
Eur. Heart J., September 2, 2002; 23(18): 1415 - 1416.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. W. Emery, F. Eales, C. H. Van Meter Jr, M. B. Knudson, E. E. Solien, and K. S. Tweden
Ventriculocoronary artery bypass results using a mesh-tipped device in a porcine model
Ann. Thorac. Surg., September 1, 2001; 72(3): S1004 - 1008.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1975 by the American College of Chest Physicians.