Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weinstein, R.
Right arrow Articles by Stamm, W.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Weinstein, R.
Right arrow Articles by Stamm, W.

Chest, Vol 69, 338-344, Copyright © 1976 by American College of Chest Physicians


ARTICLES

Pressure transducers as a source of bacteremia after open heart surgery. Report of an outbreak and guidelines for prevention

RA Weinstein, TG Emori, RL Anderson and WE Stamm

During four weeks in 1974, eight (26 percent) of 31 intensive care unit patients who had undergone open-heart surgery developed symptomatic Pseudomonas cepacia bacteremia in the intensive care unit one to three days after the open-heart surgery. An investigation demonstrated that operating room pressure transducers were being contaminated during cleaning with a detergent that contained P cepacia at the rate of 10(4) organisms per milliliter and that the organisms were transmitted to patients after open-heart surgery as a result of one to three days of contact with transducer-monitoring lines used in the operating room and brought to the intensive care unit with the patient. Pressure- transducer contamination, a frequently unappreciated but preventable cause of nosocomial bacteremia, can be minimized by sterilizing transducers between use on different patients by paying strict attention to aseptic technique when setting up, calibrating, and using monitoring systems; and by changing transducers, tubing, and monitoring fluid for each monitored patient at regular intervals.


This article has been cited by other articles:


Home page
PediatricsHome page
N. P. O'Grady, M. Alexander, E. P. Dellinger, J. L. Gerberding, S. O. Heard, D. G. Maki, H. Masur, R. D. McCormick, L. A. Mermel, M. L. Pearson, et al.
Guidelines for the Prevention of Intravascular Catheter-Related Infections