Chest Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Citron, P.
Right arrow Articles by Kahn, A. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Citron, P.
Right arrow Articles by Kahn, A. R.

Chest, Vol 73, 193-197, Copyright © 1978 by American College of Chest Physicians


ARTICLES

Clinical experience with a new transvenous atrial lead

P Citron, NP Smyth, M Kleinert and AR Kahn

Although systems using atrial pacemakers offer potential clinical advantages for many patients now receiving ventricular devices, atrial systems have been used in less than 1% of the implantations of permanent pacemakers. The unavailability of clinically successful, easily positioned atrial leads is regarded as the most significant factor in the underutilization of atrial pacing systems. A permanent transvenous atrial lead has been developed and has performed well in 16 months of evaluation in 28 patients. Acute thresholds for voltage at a pulse width of 1 msec ranged from 0.40 v to 2.0 v (average, 1.1 v). Acute peak-to-peak amplitudes of the atrial electrogram were notably high, ranging from 2.5 mv to 7.5 mv (average, 5.1 mv) as measured oscilloscopically. Intermittent failure of sensing occurred in three patients during the period immediately after implantations. Spontaneous dislodgment of the lead from the right atrial appendage occurred in two patients. Atrial sensing and pacing functions remained intact in the first case, and no revision was performed. The lead was repositioned in the second patient and has remained in good position. No complications relating to the lead have been noted in the remaining patients.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1978 by the American College of Chest Physicians.