Guest Access | Sign In via User Name/Password |
|||||||||
Chest, Vol 74, 362-368, Copyright © 1978 by American College of Chest Physicians
ARTICLES |
CE Lindholm, B Ollman, JV Snyder, EG Millen and A Grenvik
The flexible fiberoptic bronchoscope is used increasingly often as a multipurpose instrument in critical care medicine. In poor risk patients who need continuous mechanical ventilation, rigid open tube bronchoscopy is a problem. With the flexible fiberoptic bronchoscope, however, diagnostic and therapeutic procedures can be carried out without interruption of ongoing mechanical ventilation. This procedure offers the possibility of bronchoscopy with reduced risk in debilitated patients. However, in these critically ill patients, the cardiopulmonary system is functioning at the borderline of its ability. Therefore, even the small changes in ventilation pattern caused by flexible fiberoptic bronchoscopy (FFB) may in some cases cause dangerous cardiopulmonary distress. For example, changes of intrabronchial pressure, tidal volume, PaO2, PaCO2 and cardiac output may be caused by the procedure. Further, it is of great importance to restrict suction through the instrument to short periods to avoid dangerous alterations in the ventilation perfusion relationship. Since serious complications may occur, it is mandatory that the bronchoscopist be aware of the potential pathophysiologic effects of FFB during mechanical ventilation of critically ill patients.
This article has been cited by other articles:
![]() |
G. D. Perkins, S. Chatterjee, S. Giles, D. F. McAuley, S. Quinton, D. R. Thickett, and F. Gao Safety and Tolerability of Nonbronchoscopic Lavage in ARDS Chest, April 1, 2005; 127(4): 1358 - 1363. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. E. Kreider and D. A. Lipson Bronchoscopy for Atelectasis in the ICU: A Case Report and Review of the Literature Chest, July 1, 2003; 124(1): 344 - 350. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Antonelli, G. Conti, M. Rocco, A. Arcangeli, F. Cavaliere, R. Proietti, and G. U. Meduri Noninvasive Positive-Pressure Ventilation vs Conventional Oxygen Supplementation in Hypoxemic Patients Undergoing Diagnostic Bronchoscopy* Chest, April 1, 2002; 121(4): 1149 - 1154. [Abstract] [Full Text] [PDF] |
||||
![]() |
J Dakin and M Griffiths The pulmonary physician in critical care 1: Pulmonary investigations for acute respiratory failure Thorax, January 1, 2002; 57(1): 79 - 85. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. W. McCain, D. P. Dunagan, N. E. Adair, and R. Chin Jr. Prospective Randomized Trial Comparing Oxygen Administration During Nasal Flexible Bronchoscopy : Oral vs Nasal Delivery Chest, November 1, 2001; 120(5): 1671 - 1674. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Lawson, J. I. Peters, and D. C. Shelledy Effects of Fiberoptic Bronchoscopy During Mechanical Ventilation in a Lung Model Chest, September 1, 2000; 118(3): 824 - 831. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. MAITRE, S. JABER, S. M. MAGGIORE, E. BERGOT, J. C. RICHARD, H. BAKTHIARI, B. HOUSSET, G. BOUSSIGNAC, and L. BROCHARD Continuous Positive Airway Pressure during Fiberoptic Bronchoscopy in Hypoxemic Patients . A Randomized Double-Blind Study Using A New Device Am. J. Respir. Crit. Care Med., September 1, 2000; 162(3): 1063 - 1067. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |