Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fowles, R.
Right arrow Articles by Popp, R.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Fowles, R.
Right arrow Articles by Popp, R.

Chest, Vol 75, 434-440, Copyright © 1979 by American College of Chest Physicians


ARTICLES

Two-dimensional echocardiographic features of bicuspid aortic valve

RE Fowles, RP Martin, JM Abrams, JN Schapira, JW French and RL Popp

The two-dimensional cross-sectional echocardiographic diagnosis of bicuspid aortic valves is described and compared with results of M-mode echocardiograms. Aortic valve anatomy was determined in 19 selected patients by angiography, and confirmed in five by direct surgical visualization. Using an eccentricity index (EI) of 1.3 or greater as diagnostic of bicuspid aortic valve, M-mode correctly identified anatomy in 14 of 19 valves (74 percent), although EI varied in several patients. For two-dimensional diagnosis of bicuspid aortic valve, short axis cross section was preferred, and criteria included number of cusps seen in real time motion, irregularity of folding of cusp margins, and location of commissural insertions. Two-dimensional echocardiography correctly identified anatomy in 18 of 19 valves (95 percent). Long axis cross section disclosed valvular doming in all 8 patients in whom doming was observed angiographically, correlating with hemodynamic findings. Two-dimensional echocardiography aids in the detection of bicuspid aortic valve in a suspected population, can give an estimate of valve gradients, and explains variability in M-mode findings. As such, two-dimensional echocardiography is a valuable tool in the noninvasive diagnosis of the bicuspid aortic valve.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1979 by the American College of Chest Physicians.