Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Orta, D.
Right arrow Articles by Olsen, G.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Orta, D., Jr
Right arrow Articles by Olsen, G.

Chest, Vol 76, 269-273, Copyright © 1979 by American College of Chest Physicians


ARTICLES

Segmental pulmonary angiography in the critically-ill patient using a flow-directed catheter

DA Orta Jr, S Eisen, BM Yergin and GN Olsen

Selective pulmonary angiography was performed using a flow-directed, balloon-tipped catheter in 20 consecutive intensive care unit patients requiring heart catheterizations on the right side for hemodynamic monitoring. No morbidity was encountered from this procedure. Adequate quality balloon-occlusion angiographs were obtained with a portable chest roentgenogram in 17 (85 percent) but appeared normal in only 12 (60 percent), seriously limiting the usefulness of this technique in the diagnosis of occult pulmonary embolisms. With this technique, the catheter tip was found to be in a segmental pulmonary artery anterior to the left atrium (zone I) in 30 percent of the patients. From these findings, we conclude that not infrequently the catheter tip was situated in zone I anterior to the left atriums. Slective pulmonary angiography using a flow-directed, balloon-tipped catheter proved useful in demonstrating the precise location of the catheter tip. When this is the case, the catheter tip should be relocated to a segment below the left atrium (zone III) in patients requiring positive end- expiratory pressure because the "wedge" pressure measured in zone I may not accurately reflect left atrial pressure.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1979 by the American College of Chest Physicians.