Chest Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McDowell, J.
Right arrow Articles by Thiede, W.
Right arrow Search for Related Content
PubMed
Right arrow Articles by McDowell, J.
Right arrow Articles by Thiede, W.

Chest, Vol 78, 853-855, Copyright © 1980 by American College of Chest Physicians


ARTICLES

Usefulness of the transcutaneous Po2 monitor during exercise testing in adults

JW McDowell and WH Thiede

The usefulness of the transcutaneous Po2 monitor for monitoring during stress testing was evaluated. Seventy-five simultaneous recordings of arterial and transcutaneous Po2 were made on 11 patients with chronic obstructive pulmonary disease while they were undergoing treadmill exercise testing. All arterial blood samples were drawn from an indwelling brachial arterial line and analyzed in duplicate. The range of arterial Po2 measured was 50 to 145 mm Hg. The correlation coefficient (relationship between arterial and transcutaneous Po2) was .96 and the slope of the best fit line was 1.047 (Y = 1.047 x -7.2). The transcutaneous Po2 was an average of 5.99 +/- 4.76 mm Hg below the arterial Po2 in the entire group. The mean difference in transcutaneous and arterial Po2 was greater at low Po2 level, than at high levels. We found the electrode easy to maintain and calibrate, with a low frequency of malfunction. This instrument provides a safe, simple, and reliable noninvasive method for recording serial changes in Po2 during exercise testing.


This article has been cited by other articles:


Home page
CirculationHome page
P. Abraham, J. Picquet, B. Vielle, D. Sigaudo-Roussel, F. Paisant-Thouveny, B. Enon, and J.-L. Saumet
Transcutaneous Oxygen Pressure Measurements on the Buttocks During Exercise to Detect Proximal Arterial Ischemia: Comparison With Arteriography
Circulation, April 15, 2003; 107(14): 1896 - 1900.
[Abstract] [Full Text] [PDF]