Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shasby, D.
Right arrow Articles by Hyers, T.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Shasby, D.
Right arrow Articles by Hyers, T.

Chest, Vol 80, 666-670, Copyright © 1981 by American College of Chest Physicians


ARTICLES

Swan-Ganz catheter location and left atrial pressure determine the accuracy of the wedge pressure when positive end-expiratory pressure is used

DM Shasby, IM Dauber, S Pfister, JT Anderson, SB Carson, F Manart and TM Hyers

In 43 percent of 30 consecutive open heart surgery patients, Swan-Ganz catheter tips lodged within 1 cm of or above the left atrium. When in this position the wedge pressure measured by the catheter was not an accurate estimate of left atrial pressure when positive end-expiratory pressure (PEEP) was used, especially when left atrial pressure was low. Catheters located below the left atrium were accurate at all levels of PEEP tested. The position of Swan-Ganz catheters should be confirmed by a lateral chest roentgenogram when PEEP is used, and catheter tips not below the left atrium should be repositioned.


This article has been cited by other articles:


Home page
Crit Care NurseHome page
M. Keckeisen
Monitoring Pulmonary Artery Pressure
Crit. Care Nurse, June 1, 2004; 24(3): 67 - 70.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. K. Albert and W. J. E. Lamm
Left Atrial Pressure Can Be Accurately Transmitted to the Pulmonary Artery despite Zone 1 Conditions
Am. J. Respir. Crit. Care Med., April 1, 2003; 167(7): 1016 - 1020.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. S. Mueller, K. Chatterjee, K. B. Davis, M. A. Fifer, C. Franklin, M. A. Greenberg, A. J. Labovitz, P. K. Shah, K. J. Tuman, M. H. Weil, et al.
Present use of bedside right heart catheterization in patients with cardiac disease
J. Am. Coll. Cardiol., September 1, 1998; 32(3): 840 - 864.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American College of Chest Physicians.