Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Viquerat, C. E.
Right arrow Articles by Suter, P. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Viquerat, C. E.
Right arrow Articles by Suter, P. M.

Chest, Vol 83, 509-514, Copyright © 1983 by American College of Chest Physicians


ARTICLES

Biventricular volumes and function in patients with adult respiratory distress syndrome ventilated with PEEP

CE Viquerat, A Righetti and PM Suter

The ventricular volume and function changes induced by the addition of 12 cm H2O of positive end-expiratory pressure (PEEP) during mechanical ventilation were studied in 11 patients with the adult respiratory distress syndrome. Cardiac output was measured by thermodilution and ventricular ejection fraction by the multiple gated equilibrated cardiac blood pool scintigraphy. Right and left end-diastolic volumes were then calculated by dividing stroke volume by ejection fraction. The PEEP caused a 14 percent decrease of the cardiac output secondary to a decrease in stroke volume. On the basis of the relationship between stroke volume and ventricular end-diastolic volume, we conclude that reduction in preload was the major component of the decrease in cardiac output. After removal of PEEP, we observed a rebound phenomenon characterized by higher values for stroke volume and cardiac output than before the application of PEEP.


This article has been cited by other articles:


Home page
ChestHome page
M. Cepkova, V. Kapur, X. Ren, T. Quinn, H. Zhuo, E. Foster, K. D. Liu, and M. A. Matthay
Pulmonary Dead Space Fraction and Pulmonary Artery Systolic Pressure as Early Predictors of Clinical Outcome in Acute Lung Injury
Chest, September 1, 2007; 132(3): 836 - 842.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
S. K. Frazier, K. S. Stone, D. Moser, R. Schlanger, C. Carle, L. Pender, J. Widener, and H. Brom
Hemodynamic Changes During Discontinuation of Mechanical Ventilation in Medical Intensive Care Unit Patients
Am. J. Crit. Care., November 1, 2006; 15(6): 580 - 593.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
F. MICHARD, D. CHEMLA, C. RICHARD, M. WYSOCKI, M. R. PINSKY, Y. LECARPENTIER, and J.-L. TEBOUL
Clinical Use of Respiratory Changes in Arterial Pulse Pressure to Monitor the Hemodynamic Effects of PEEP
Am. J. Respir. Crit. Care Med., March 1, 1999; 159(3): 935 - 939.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1983 by the American College of Chest Physicians.