|
|
||||||||
Guest Access | Sign In via User Name/Password |
|||||||||
Chest, Vol 83, 615-620, Copyright © 1983 by American College of Chest Physicians
ARTICLES |
MJ Tobin, G Jenouri, B Lind, H Watson, A Schneider and MA Sackner
The assumption that the respiratory system behaves with 2 df of motion in healthy persons allows calibration of respiratory inductive plethysmography (RIP) with spirometry (SP). To ascertain whether RIP could be calibrated by the same assumption in patients with lung disease, even though at least 3 df of motion are visualized (ie, upper and lower rib cage and upper and lower abdomen move out of phase), RIP was calibrated by a two-position calibration procedure and validated satisfactorily by simultaneous SP in the erect, semirecumbent, supine, and lateral decubitus positions. In lung disease, the contribution to tidal volume of regions moving independently of the combined rib cage and abdominal movements either is small or remains relatively constant with change of body posture. For clinical monitoring of the resting breathing pattern where patient movements cannot be restricted, respiratory inductive plethysmography can serve as a reliable semiquantitative, noninvasive ventilatory monitoring device.
This article has been cited by other articles:
![]() |
J. B. Borges, V. N. Okamoto, G. F. J. Matos, M. P. R. Caramez, P. R. Arantes, F. Barros, C. E. Souza, J. A. Victorino, R. M. Kacmarek, C. S. V. Barbas, et al. Reversibility of Lung Collapse and Hypoxemia in Early Acute Respiratory Distress Syndrome Am. J. Respir. Crit. Care Med., August 1, 2006; 174(3): 268 - 278. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. H. Mayer, R. G. Clayton Sr, A. F. Jawad, J. M. McDonough, and J. L. Allen Respiratory Inductance Plethysmography in Healthy 3- to 5-Year-Old Children Chest, November 1, 2003; 124(5): 1812 - 1819. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. H. Wilhelm, W. T. Roth, and M. A. Sackner The LifeShirt: An Advanced System for Ambulatory Measurement of Respiratory and Cardiac Function Behav Modif, October 1, 2003; 27(5): 671 - 691. [Abstract] [PDF] |
||||
![]() |
S. Solway, D. Brooks, L. Lau, and R. Goldstein The Short-term Effect of a Rollator on Functional Exercise Capacity Among Individuals With Severe COPD* Chest, July 1, 2002; 122(1): 56 - 65. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. HEINDL, M. LEHNERT, C.-P. CRIEE, G. HASENFUSS, and S. ANDREAS Marked Sympathetic Activation in Patients with Chronic Respiratory Failure Am. J. Respir. Crit. Care Med., August 15, 2001; 164(4): 597 - 601. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Miller, A. M. Hoffman, and J. Hunter Thoracoabdominal asynchrony failed to grade airway obstructions in foals J Appl Physiol, June 1, 2000; 88(6): 2081 - 2087. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |