Chest Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thomsen, J. H.
Right arrow Articles by Polcyn, R. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thomsen, J. H.
Right arrow Articles by Polcyn, R. E.

Chest, Vol 84, 6-13, Copyright © 1983 by American College of Chest Physicians


ARTICLES

Estimation of absolute left ventricular volume from gated radionuclide ventriculograms. A method using phase image assisted automated edge detection and two-dimensional echocardiography

JH Thomsen, AK Patel, BR Rowe, RS Hellman, P Kosolcharoen, AJ Feiring, T Filipek, JR Halama and RE Polcyn

Twenty-four patients underwent gated cardiac blood pool (GBP) imaging, two-dimensional echocardiography (2-D echo), and single-plane contrast ventriculography (within 24 hours). Variable left ventricular (LV) regions of interest on GBP images were identified by an automated threshold radial search. To avoid excluding LV counts we indexed the search threshold to the threshold identified by a phase image generated by Fourier analysis. LV depth calculated by 2-D echo was used for attenuation correction of LV counts. LV end-diastolic volume (EDV) and end-systolic volume (ESV) were calculated by dividing attenuation, background and deadtime corrected LV count rates by the background corrected count rate/ml of venous blood drawn during the study. Correlations between radionuclide and contrast volumes were good (EDV + ESV r = 0.97, EDV r = 0.94, ESV r = 0.95). Regression lines were close to the lines of identity. This method, in which GBP imaging and automated LV edge finding are complemented by 2-D echo for count attenuation correction, demonstrated reliable and reproducible noninvasive estimates of absolute LV volume.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
S. Klotz, I. Hay, M. L. Dickstein, G.-H. Yi, J. Wang, M. S. Maurer, D. A. Kass, and D. Burkhoff
Single-beat estimation of end-diastolic pressure-volume relationship: a novel method with potential for noninvasive application
Am J Physiol Heart Circ Physiol, July 1, 2006; 291(1): H403 - H412.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1983 by the American College of Chest Physicians.